We observed a significant decrease in atrial natriuretic peptide levels after the Cox maze procedure. This may be one of the possible causes of fluid retention after this procedure. These decreased atrial natriuretic peptide levels after the Cox maze procedure may result from the multiple atriotomy incisions and excision of both atrial auricles performed during the procedure, rather than from the conversion of atrial fibrillation to normal sinus rhythm.