1983
DOI: 10.1002/jhrc.1240061213
|View full text |Cite
|
Sign up to set email alerts
|

Adaptation of moving‐wire flame ionization detector to accept total effluent in micro‐liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1986
1986
2005
2005

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…The direction of vosm depends on the sign of the surface charge of the packing materials, and its value depends on the amount of surface charge, pH, concentration of electrolyte in the eluent, composition of the eluent, etc. [8,10,11].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The direction of vosm depends on the sign of the surface charge of the packing materials, and its value depends on the amount of surface charge, pH, concentration of electrolyte in the eluent, composition of the eluent, etc. [8,10,11].…”
Section: Resultsmentioning
confidence: 99%
“…In general, vOSm [15,16] and vmob [11,17] are expressed as (7) where E (defined as E = E~D ) and D are the (dimensionless) dielectric constant or relative permittivity (D = E / E , where c0 is the permittivity of free space), and AE, {, and C* are potential gradient, zeta potential, viscosity, and a constant, respectively. The value of 7 for 40% methanol/water solution at 20°C is about 1.8 cP, and the value gradually decreases to ca.…”
Section: Microcolumn Separations Vol 6 No 2 1994mentioning
confidence: 99%
“…The first approach has the main disadvantage of the very likely risk of sample loss and is therefore hardly applied as an interface. Tsuda et al [189] and Veening et al [190] have reported on the use of a moving-wire flame ionization detector for capillary and micro LC, respectively. Typical mass limits of detection were 10-20 ng for triolin with the capillary LC system, and 160 and 400 ng for xylose and lactose with the micro LC system.…”
Section: Gas Chromatographic Detectorsmentioning
confidence: 99%
“…The analytes should be nonvolatile to be seen by the FID. Tsuda et al (117) and Veening et al (118) combined mLC and FID via a moving-wire interface. All these systems had a complex design and the loss of volatile analytes during solvent evaporation did not make them very useful.…”
Section: Htlc-fid (Flame Ionization Detection)mentioning
confidence: 99%