“…The values used in our model have been experimentally defined, by the comparison between simulated signals and physiological signals. In this work we have used, for the systemic circulation that is constituted of a single loop, the parameter values of McInnis et al (1985), except for the vena cava that comes from Olufsen et al (2005). For the other version of the model of systemic circulation, the aorta parameter values has been obtained from McInnis et al (1985), the arteries values come from Olufsen et al (2005) and the venous values are taken from Heldt et al (2002).…”
Section: Model Of the Circulatory Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The values used in our model have been experimentally defined, by the comparison between simulated signals and physiological signals. In this work we have used, for the systemic circulation that is constituted of a single loop, the parameter values of McInnis et al (1985), except for the vena cava that comes from Olufsen et al (2005). For the other version of the model of systemic circulation, the aorta parameter values has been obtained from McInnis et al (1985), the arteries values come from Olufsen et al (2005) and the venous values are taken from Heldt et al (2002).…”
Section: Model Of the Circulatory Systemmentioning
confidence: 99%
“…For the other version of the model of systemic circulation, the aorta parameter values has been obtained from McInnis et al (1985), the arteries values come from Olufsen et al (2005) and the venous values are taken from Heldt et al (2002). For both models, the parameters of the pulmonary circulation model are those of McInnis et al (1985). For example, the values of the parameters of the aorta are: C = 0.2199 ml/mmHg, R = 0.0675 mmHg.s/ml and I = 0.000825 mmHg.s/sml.…”
Section: Model Of the Circulatory Systemmentioning
confidence: 99%
“…Also, prior approaches have mostly been applied to LPN layouts with few elements or have made use of a priori information to significantly reduce the number of parameters. Finally, although many studies in the literature (see, e.g., [15, 17, 20–24]) employ a Bayesian representation of the unknown parameters through a vector of random variables, they often aim primarily to determine optimal parameter estimates, without deriving associated confidence metrics.…”
Section: Introductionmentioning
confidence: 99%
“…Similar systems can also be assembled by coupling 3D CFD models with 1D peripheral counterparts. While techniques for parameter estimation and data assimilation in lumped circulation networks have been proposed in the literature (see, e.g., Spilker and Taylor, 2010, Revie et al, 2013, Sughimoto et al, 2013, Yu et al, 2001, Xiao et al, 2002, Deswysen, 1977, Clark et al, 1980, Deswysen et al, 1980, McInnis et al, 1985, Shimooka et al, 1991, Avanzolini et al, 1992, Ruchti et al, 1993, Yu et al, 1998), the computational cost of solving the coupled 0D/3D problem has prevented extension of these techniques to multiscale models.…”
Section: Introductionmentioning
confidence: 99%