Adaptive Noise Cancellation Using Accelerometers for the PPG Signal from Forehead

Abstract: For the upcoming ubiquitous computing environments in the u-health areas involve the measurement of physiological signals in the daily life. However, the measurement of those signals, such as the photoplethysmorgraphy (PPG), and the electrocardiogram (ECG), requires being still tight during the measurement in order to get the accurate result preventing noises caused by the casual movement. In this paper, we propose a method to obtain the accurate physiological signals in the situation where the little movement… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
31
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 56 publications
(31 citation statements)
references
References 4 publications
0
31
0
Order By: Relevance
“…The method can be used in many parts of the body, such as the forehead [3] and ear [4], and is very popular in emerging smartwatch devices placed on the wrist. However, the PPG recording modality has two significant limitations: PPG signals are highly corrupted by motion artifacts [5] which historically have restricted its use to no-motion situations; and the {delaram.jarchi,alex.casson}@manchester.ac.uk light source requires a large amount of power (typically approximately 1 mW) limiting the operational life of highly miniaturized wearables with small batteries.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The method can be used in many parts of the body, such as the forehead [3] and ear [4], and is very popular in emerging smartwatch devices placed on the wrist. However, the PPG recording modality has two significant limitations: PPG signals are highly corrupted by motion artifacts [5] which historically have restricted its use to no-motion situations; and the {delaram.jarchi,alex.casson}@manchester.ac.uk light source requires a large amount of power (typically approximately 1 mW) limiting the operational life of highly miniaturized wearables with small batteries.…”
Section: Introductionmentioning
confidence: 99%
“…For example, proposed methods are based on Empirical Mode Decomposition (EMD) [6], Independent Component Analysis (ICA) [7], Kalman filtering [8], adaptive filters [3], [9] and sparse signal reconstruction [10]. These have shown to be to able to extract the average heart rate from a motion contained PPG trace to within (approximately) ±5 beats-per-minute (bpm).…”
Section: Introductionmentioning
confidence: 99%
“…Different from conventional pulse oximeter probes, these sensor assemblies appear in the form of adhesive patch, finger ring, earring, earphone and headband [39] [40]. As an example, the finger-ring sensor developed by Asada et al measured PPG signals at the base of the finer to extract SpO2 and heart rate information, and wirelessly sent them to a host computer.…”
Section: Cardiac Activity and Spo2 Monitoringmentioning
confidence: 99%
“…We made experiments on measuring the PPG signal at the forehead and concluded PPG can be measured at the forehead with the Biopac system. Also, we tested the correlation between the distorted PPG signal and the acceleration signal, and designed an adaptive filter to reduce motion artifacts [7,8].…”
Section: Introductionmentioning
confidence: 99%