2016
DOI: 10.3390/ijms17091439
|View full text |Cite
|
Sign up to set email alerts
|

Adhesion, Proliferation and Migration of NIH/3T3 Cells on Modified Polyaniline Surfaces

Abstract: Polyaniline shows great potential and promises wide application in the biomedical field thanks to its intrinsic conductivity and material properties, which closely resemble natural tissues. Surface properties are crucial, as these predetermine any interaction with biological fluids, proteins and cells. An advantage of polyaniline is the simple modification of its surface, e.g., by using various dopant acids. An investigation was made into the adhesion, proliferation and migration of mouse embryonic fibroblasts… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 22 publications
1
13
0
Order By: Relevance
“…Immersion of PANi‐coated conduits into saline for at least 5 days can remove the doping acid and other small molecules introduced in the process of synthesis and thus reduce the possible cytotoxicity . The cytocompatibility of the intact PANi coating on zein film showed good for both PC 12 cells and NIH 3 T3 cells (Figure ), which was consistent with published works …”
Section: Disscusionsupporting
confidence: 89%
See 1 more Smart Citation
“…Immersion of PANi‐coated conduits into saline for at least 5 days can remove the doping acid and other small molecules introduced in the process of synthesis and thus reduce the possible cytotoxicity . The cytocompatibility of the intact PANi coating on zein film showed good for both PC 12 cells and NIH 3 T3 cells (Figure ), which was consistent with published works …”
Section: Disscusionsupporting
confidence: 89%
“…[33][34][35] The cytocompatibility of the intact PANi coating on zein film showed good for both PC 12 cells and NIH 3 T3 cells (Figure 2), which was consistent with published works. 36,37 Direct nerve repair is preferred when the gap is small and two ends can be approximated with minimal tension. 38 When the gap is longer than 5 mm, direct microsurgery will cause the tension of nerve fibers.…”
Section: Disscusionmentioning
confidence: 99%
“…The first one is used in standard procedures for testing nanomaterial and for studying material biocompatibility. 45 SDs were less than 14%. DHHP, 1,1-diphenyl-2-picrylhydrazyl ingredients.…”
Section: Evaluation Of the Pyomelanin Cytotoxicitymentioning
confidence: 77%
“…This was performed through three different but complementary methods for two different cell lines, namely mouse fibroblast (NIH3T3) and human keratinocyte (HaCaT). The first one is used in standard procedures for testing nanomaterial and for studying material biocompatibility . Keratinocytes were selected since it is the most abundant cells of epithelial layer of the skin.…”
Section: Resultsmentioning
confidence: 99%
“…The cell compatibility was detected according to previously described procedures [37]. The test samples (films Col/Chi, Col/Chi-Ta and DC-Col/Chi) were sterilized by UV radiation prior to testing.…”
Section: Cell Adhesion and Proliferation Studiesmentioning
confidence: 99%