2020 International Conference on Electrotechnical Complexes and Systems (ICOECS) 2020
DOI: 10.1109/icoecs50468.2020.9278498
|View full text |Cite
|
Sign up to set email alerts
|

Advanced plasma electrolysis research equipment with in-situ process diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…No-filler epoxy glue was used as a dielectric acoustic couplant; AES is band piezoelectric sensor П111-(0.02-0.3) (Russia); PA is 2-cascade broadband filter amplifier MSAE-FA010 (Russia); ADC is 4-channel 12-bit Advantech PCI-1714 board (Taiwan); ID is 2-cascade broadband preamplifier with zero gain (own make). The results of approbation demonstrated the operability of this measurement circuit with the possibility of amplifying acoustic signals without increasing the level of electrical crosstalk that unavoidably accompany measurements during PEO and that prevailed over the level of AE signals in other measurement circuits reviewed (AE registration through a bath [3]; through the air with a microphone [6]; through a waveguide welded to the specimen; immersionally, by immersion of the insulated AES in a bath). The operability of the proposed measurement circuit was confirmed using a calibrated acoustic pulse generator MSAE-UCA01 (Russia) according to technique [8].…”
Section: Experimental Materials and Methodsmentioning
confidence: 89%
See 2 more Smart Citations
“…No-filler epoxy glue was used as a dielectric acoustic couplant; AES is band piezoelectric sensor П111-(0.02-0.3) (Russia); PA is 2-cascade broadband filter amplifier MSAE-FA010 (Russia); ADC is 4-channel 12-bit Advantech PCI-1714 board (Taiwan); ID is 2-cascade broadband preamplifier with zero gain (own make). The results of approbation demonstrated the operability of this measurement circuit with the possibility of amplifying acoustic signals without increasing the level of electrical crosstalk that unavoidably accompany measurements during PEO and that prevailed over the level of AE signals in other measurement circuits reviewed (AE registration through a bath [3]; through the air with a microphone [6]; through a waveguide welded to the specimen; immersionally, by immersion of the insulated AES in a bath). The operability of the proposed measurement circuit was confirmed using a calibrated acoustic pulse generator MSAE-UCA01 (Russia) according to technique [8].…”
Section: Experimental Materials and Methodsmentioning
confidence: 89%
“…Many authors noted [2][3][4][5][6] that in order to obtain high-quality PEO oxide layers on non-ferrous alloys it is necessary to monitor the oxidation process in situ at the structural level. Concurrently, the problem is most vital for PEO of casing-type products with a complex shape (cylinder blocks, compressor housings, etc.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…We used the PEO equipment (USATU, Ufa, Russia) in pulsed unipolar mode [ 37 ]. The pulse amplitude was 480 V, frequency 700 Hz, duty cycle 26%.…”
Section: Methodsmentioning
confidence: 99%
“…In situ impedance spectroscopy was performed in separate PEO experiments with the frequency sweep according to the method described elsewhere [ 36 , 43 , 44 ]. The equipment details and calibration have been previously discussed [ 45 ]. A step scan was used in the range from 20 Hz to 10 kHz.…”
Section: Methodsmentioning
confidence: 99%