IEEE Power Engineering Society Summer Meeting,
DOI: 10.1109/pess.2002.1043275
|View full text |Cite
|
Sign up to set email alerts
|

Advanced steady-state models of UPFC for power system studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…8.The objectives considered are minimization of total cost including installation cost and maximization of loadability as an added constraint. From the figure, it is clear that Line 10 (6-8) followed by lines (10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22) and (29-30) are ideal locations for the placement of UPFC.…”
Section: Ieee 30 Bus Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…8.The objectives considered are minimization of total cost including installation cost and maximization of loadability as an added constraint. From the figure, it is clear that Line 10 (6-8) followed by lines (10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22) and (29-30) are ideal locations for the placement of UPFC.…”
Section: Ieee 30 Bus Systemmentioning
confidence: 99%
“…From this figure, it is clearly seen that NSGA-II algorithm is able to generate Pareto-front in a single simulation run. The ideal locations of UPFC placement are lines (6-9), (10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) and (30-31).The cost and loadability corresponding to the extreme points of NSGA-II and reference Pareto-front are given in Table 10. The cost corresponding to the loadability extreme point obtained in NSGA-II method is 75.734e 6 dollars.…”
Section: Ieee 30 Bus Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Most studies concentrate on unified power flow controller (UPFC) modeling procedures [34][35][36], optimal location methodologies [37][38][39], and various control strategies to operate UPFC [40]. However, the nature of its construction means that UPFC cannot control multiple lines.…”
Section: Introductionmentioning
confidence: 99%
“…The congestion management in power system is possible with the selection of suitable location and settings of its control parameters [12]. An effective injection modeling approaches to power flow analysis in the presence of UPFC is discussed in [13][14][15]. Power Injection Model (PIM) of UPFC and its effect, based on location are analyzed in [16,17].…”
Section: Introductionmentioning
confidence: 99%