1997
DOI: 10.1093/oxfordjournals.rpd.a031921
|View full text |Cite
|
Sign up to set email alerts
|

Advances in Superheated Drop (Bubble) Detector Techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1998
1998
2011
2011

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Passive pen-detectors have been developed with optical or volumetric registration of the bubbles, as well as active counters detecting bubble nucleations acoustically. 3,4 A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e., a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons.…”
Section: Introductionmentioning
confidence: 99%
“…Passive pen-detectors have been developed with optical or volumetric registration of the bubbles, as well as active counters detecting bubble nucleations acoustically. 3,4 A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e., a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons.…”
Section: Introductionmentioning
confidence: 99%
“…Several devices based on this technology have been designed. 7 Some are active counters acoustically detecting the sound pulses emitted when drops vaporize. Recent versions perform pulse shape analysis, record the exposure time-history and provide dose rate estimates.…”
Section: Introductionmentioning
confidence: 99%
“…Bubble detectors [16][17][18] are suspensions of over-expanded halocarbon and/or hydrocarbon droplets (about 100 µmin diameter) which vaporise upon exposure to the high LET recoils from neutron interactions. The superheated droplets are dispersed in a gel-like medium contained in a vial and act as continuously sensitive, miniature, bubble chambers.…”
Section: Instrumentationmentioning
confidence: 99%