Advantages and limitations of coupling isotachophoresis and comprehensive isotachophoresis–capillary electrophoresis to time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
60
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(60 citation statements)
references
References 37 publications
0
60
0
Order By: Relevance
“…The influence of flow rates of nebulizing and drying gas has been evaluated separately for coaxial sheath flow interfaces in different setups [95]. Especially elevated flow rates of nebulizing gas are known to cause a hydrodynamic flow inside the CE separation capillary due to an aspiration effect caused by a pressure drop at the capillary tip [26,[95][96][97]. Consequently, resolution of proteins and peptides gets impaired and sometimes is completely abolished (Figs.…”
Section: Influence Of Instrumental Parameters On Esi Processmentioning
confidence: 99%
“…The influence of flow rates of nebulizing and drying gas has been evaluated separately for coaxial sheath flow interfaces in different setups [95]. Especially elevated flow rates of nebulizing gas are known to cause a hydrodynamic flow inside the CE separation capillary due to an aspiration effect caused by a pressure drop at the capillary tip [26,[95][96][97]. Consequently, resolution of proteins and peptides gets impaired and sometimes is completely abolished (Figs.…”
Section: Influence Of Instrumental Parameters On Esi Processmentioning
confidence: 99%
“…Thus, ITP is mainly used as an on-line preconcentration step prior to CZE (transient-ITP). This is clearly shown in a recent publication by Peterson et al [66]. For low concentration of peptides ITP caused discrimination in the ESI-MS, whereas the comprehensive ITP-CZE-MS approach offered a loadability of 10 mL in conjunction with separation in the CZE and on-line MS detection.…”
Section: Itp-msmentioning
confidence: 88%
“…The combination of two highly resolving and orthogonal separation techniques of CIEF and RPLC or CZE, together with analyte focusing and concentration, significantly enhances the dynamic range and sensitivity of conventional MS towards the identification of low-abundance ITP-CZE not only enables the increase of loadability but can be used in a comprehensive way, as shown in an ITP-CZE-MS approach by Peterson et al [66]. However, the ITP as the first dimension does not show the resolution as, e.g., the CIEF-approach.…”
Section: Applications To Multidimensional and Integrated Approaches Cmentioning
confidence: 99%
“…Comprehensive ITP-CZE was successfully coupled to electrospray ionization orthogonal acceleration time-of-flight mass spectrometry using angiotensin peptides as model analytes (Peterson et al, 2003). ITP-TOF-MS alone was adequate for the separation and detection of high concentration samples.…”
Section: Itp-czementioning
confidence: 99%