Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedi
DOI: 10.1109/iembs.1998.747076
|View full text |Cite
|
Sign up to set email alerts
|

AIDA on-line: a glucose and insulin simulator on the WWW

Abstract: A glucose and insulin simulator, AIDA on-line, was completed to fulfill a senior design project and is available for educational purposes through the World Wide Web 0. Designed to be accessible and usable by anyone who desires to learn more about diabetes, AIDA on-line is available through The Shodor Education Foundation at http://www.shodor.org/aida/.The code for the WWW version was written in Perl and relies heavily on previously completed work on the AIDA glucose-insulin simulator. AIDA on-line allows the u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Large swings in meal carbohydrate intakes result in obvious swings in BG levels that require adjustments to be made to insulin injections to correct the perturbations in the simulated patient. As has been highlighted previously by Blanchard et al, the advantage of having multiple preprogrammed simulated “patients” allows the user to see the effect of these changes on different body types that have various insulin sensitivities [ 41 ].…”
Section: Methodsmentioning
confidence: 99%
“…Large swings in meal carbohydrate intakes result in obvious swings in BG levels that require adjustments to be made to insulin injections to correct the perturbations in the simulated patient. As has been highlighted previously by Blanchard et al, the advantage of having multiple preprogrammed simulated “patients” allows the user to see the effect of these changes on different body types that have various insulin sensitivities [ 41 ].…”
Section: Methodsmentioning
confidence: 99%
“…More specifically, results have been obtained by loading into the used artificial glucometer some realistic glycemia values of a diabetic patient recorded during a whole day. For such a goal, glucose values to be transmitted have been obtained from AIDA web site (AIDA, 2010), that is an on-line educational simulator designed to assist interested parties in obtaining a better understanding of how insulin and glucose interact within the body (Blanchard, 1998). More specifically, one of the sample cases proposed on the AIDA web site (the number 0015 referring to the virtual patient named "Edward Carllson"), has been chosen, and the virtual patient's blood glucose values have been charged on the artificial glucometer connected to the S-Tag.…”
Section: Benchmarking the S-tagmentioning
confidence: 99%
“…12, for instance, the reported results refer to the blood glucose monitoring in the range 4 -12 mmol/ l. More specifically, results have been obtained by loading into the used artificial glucometer some realistic glycemia values of a diabetic patient recorded during a whole day. For such a goal, glucose values to be transmitted have been obtained from AIDA web site (AIDA, 2010), that is an on-line educational simulator designed to assist interested parties in obtaining a better understanding of how insulin and glucose interact within the body (Blanchard, 1998). More specifically, one of the sample cases proposed on the AIDA web site (the number 0015 referring to the virtual patient named " Edward Carllson" ), has been chosen, and the virtual patient's blood glucose values have been charged on the artificial glucometer connected to the S-Tag.…”
Section: Benchmarking the S-tagmentioning
confidence: 99%