2011
DOI: 10.1016/j.buildenv.2011.06.009
|View full text |Cite
|
Sign up to set email alerts
|

Air permeability measurements of dwellings and building components in Portugal

Abstract: a b s t r a c tVentilation represents a significant part of heat loss in winter, leading to the need to minimize airflow. However, it is absolutely necessary to ensure indoor air quality and the safety of the users and to control the risk of condensation. Ventilation is responsible on average for 30%e40% of energy consumption in air conditioning in Western European buildings. There is great variability in air change rates (ACH [h À1 ]) from country to country and the minimum value takes into account comfort, s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
16
0
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 43 publications
(18 citation statements)
references
References 1 publication
1
16
0
1
Order By: Relevance
“…Another Portuguese study carried our air permeability tests in five flats of a single building. Although the properties had the same size, components and construction characteristics, the results revealed wide variations in airtightness attributed to the quality of installation work [34]. Similar results were also found for nine semi-detached social housing dwellings in Ireland, where the measured and modelled airtightness result differed by up to 89% [35].…”
Section: Building Fabric Thermal Performance: Evidence To Datesupporting
confidence: 72%
“…Another Portuguese study carried our air permeability tests in five flats of a single building. Although the properties had the same size, components and construction characteristics, the results revealed wide variations in airtightness attributed to the quality of installation work [34]. Similar results were also found for nine semi-detached social housing dwellings in Ireland, where the measured and modelled airtightness result differed by up to 89% [35].…”
Section: Building Fabric Thermal Performance: Evidence To Datesupporting
confidence: 72%
“…Consequently, the flow is neither fully turbulent nor dominated by laminar characteristics and the shape of leakage paths cannot be clearly defined. The overall uncertainty in the parameters obtained with the test using standard equipment remains below 15% in most cases [4,35,45] under calm conditions.…”
Section: Resultsmentioning
confidence: 99%
“…It is deduced that one of the variables with greater relevance is the year of construction [27][28][29][30]. Also, characteristics of the building such as typology [31], type of construction [30], type of window/glazing [15] and window frame [6,32], foundation [28], construction system [33], materials [15,24,32,34], floor area [28], total height [28], number of storeys [33], ventilation system [35,36], type of insulation [30] and sealing devices [34], and management type [31] should be considered. In addition, the execution also seems to be a relevant factor in the airtightness of the envelope [36,37].…”
Section: Parametersmentioning
confidence: 99%
“…In the following sections, the building, the dwelling where the test was conducted and the respective experimental results are presented. The chosen building was studied in the context of a wider research project for which results on the permeability of the components of the ventilation system and the dwellings have already been presented [27].…”
Section: Mixed Ventilation Systems In Portugalmentioning
confidence: 99%
“…The flats had a ceiling height of approximately 2.5 m. The natural ventilation system proposed by the designer had the following characteristics and locations (Fig. 3) [27]:…”
Section: Description Of the Building And Ventilation System Testedmentioning
confidence: 99%