Air quality during the winter in Québec day-care centers.

Abstract: Over 90% of 91 day care centers in greater Montréal, Québec exceeded 1000 ppm of CO2 during January through April 1989. Four variables were independent positive predictors of CO2 levels: the density of children in the center; presence of electric heating; absence of a ventilation system; and building age. High levels of CO2 are associated with respiratory tract and other symptoms. Clear standards and inspection policies should be established for day care center air quality.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

1996
1996
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…In this study, large amounts of fungal aerospores and HDM-sensitization were both correlated to high AIH and / or previous water leak(s) or window condensation, which means that a poor indoor climate promotes growth of moulds and HDM (Wickman, 1993;Verhoeff et al, 1992). The high pC02 (21000 ppm) levels found in homes may be a further parameter for a poor indoor climate as the level of C 0 2 is an indicator of the quality of ventilation in general, and may thus serve as a marker for other pollutants (Burge, 1990;Daneault et al, 1992). On the other hand, as opposed to others (Lawenstein et al, 1986;Strachan, 1988), we found, as did Wickman (1993), no association between fungal growth and atopic diseases.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, large amounts of fungal aerospores and HDM-sensitization were both correlated to high AIH and / or previous water leak(s) or window condensation, which means that a poor indoor climate promotes growth of moulds and HDM (Wickman, 1993;Verhoeff et al, 1992). The high pC02 (21000 ppm) levels found in homes may be a further parameter for a poor indoor climate as the level of C 0 2 is an indicator of the quality of ventilation in general, and may thus serve as a marker for other pollutants (Burge, 1990;Daneault et al, 1992). On the other hand, as opposed to others (Lawenstein et al, 1986;Strachan, 1988), we found, as did Wickman (1993), no association between fungal growth and atopic diseases.…”
Section: Discussionmentioning
confidence: 99%
“…High concentration of indoor air pollutants and carbon dioxide (CO 2 ) in DCC for children has been reported, and poor indoor air quality (IAQ) and ventilation conditions were associated with higher levels of CO 2 [21,3,15,4] and with other indoor air pollutants [24].…”
Section: Introductionmentioning
confidence: 99%
“…CO 2 is considered an indirect marker of IAQ in the absence of other sources besides the anthropogenic [5]. Its concentration could be highly influenced by the number of occupants in the room [10], human behaviours and building characteristics [4]. A high CO 2 concentration suggests a low air supply which may elicit symptoms due to higher concentrations of air pollutants [21].…”
Section: Introductionmentioning
confidence: 99%
“…There is little information available about the indoor environments of daycare centers. Two studies from the USA and Canada measured CO 2 in daycare centers, and concluded that the ventilation is often inadequate, with CO 2 ‐levels exceeding 1000 ppm (Daneault et al., 1992; Ferng and Lee, 2002). In one older Swedish study, CO 2 levels were lower (458–822 ppm) (Cars et al., 1992).…”
Section: Introductionmentioning
confidence: 99%