2000
DOI: 10.1016/s0140-6736(05)73411-5
|View full text |Cite
|
Sign up to set email alerts
|

Allergy to icodextrin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
9
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 2 publications
0
9
0
Order By: Relevance
“…This is in line with pharmacokinetic properties of this agent, since icodextrin is shown to have a plasma half-life of 14.7 h and its metabolites are eliminated from plasma within 3 to 7 days after icodextrin discontinuation, depending on the residual renal function [ 15 ]. Skin tests with icodextrin-containing patches, pricks or intra-dermal tests cannot reliably confirm the diagnosis, since these re-challenging tests were unable to reproduce the skin rash in previously reported cases of acute exanthematous generalized pustulosis-like eruption that occurred shortly after exposure to icodextrin [ 4 ]. Notably, skin tests are reported to have a very low sensitivity and specificity in diagnosing such drug-induced skin reactions [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This is in line with pharmacokinetic properties of this agent, since icodextrin is shown to have a plasma half-life of 14.7 h and its metabolites are eliminated from plasma within 3 to 7 days after icodextrin discontinuation, depending on the residual renal function [ 15 ]. Skin tests with icodextrin-containing patches, pricks or intra-dermal tests cannot reliably confirm the diagnosis, since these re-challenging tests were unable to reproduce the skin rash in previously reported cases of acute exanthematous generalized pustulosis-like eruption that occurred shortly after exposure to icodextrin [ 4 ]. Notably, skin tests are reported to have a very low sensitivity and specificity in diagnosing such drug-induced skin reactions [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
“…Skin tests with icodextrin-containing patches, pricks or intra-dermal tests cannot reliably confirm the diagnosis, since these re-challenging tests were unable to reproduce the skin rash in previously reported cases of acute exanthematous generalized pustulosis-like eruption that occurred shortly after exposure to icodextrin [ 4 ]. Notably, skin tests are reported to have a very low sensitivity and specificity in diagnosing such drug-induced skin reactions [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5 Cutaneous reactions to icodextrin are estimated to occur in up to 15% of patients 6 ; however, only a limited number of cases of icodextrin-induced AGEP have been reported. [7][8][9] Each case occurred approximately 2 weeks after the initiation of icodextrin and resolved upon discontinuation. Our patient represents a case of icodextrin-associated AGEP and illustrates the need to inquire about recent changes in dialysis solutions in the diagnostic approach to a patient on dialysis who has a diffuse pustular eruption.…”
mentioning
confidence: 99%
“…The structure of icodextrin differs from that of the naturally occurring polymeric substance dextran — used as a plasma expander — only in the alpha-1,4 and alpha-1,6 linkage. Although a precise mechanism has not been identified, a putative pathophysiological mechanism may cause sensitization against icodextrin-related molecules, such as dextran, with cross-reactive antibodies, or progressive sensitization against icodextrin itself (6).…”
mentioning
confidence: 99%