2010
DOI: 10.1016/j.aca.2009.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Alternatives for sample pre-treatment and HPLC determination of Ochratoxin A in red wine using fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
28
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 72 publications
(28 citation statements)
references
References 22 publications
0
28
0
Order By: Relevance
“…The results show the response of the fluorescent aptamer is specific for OTA. To further assess whether this method can be applied to the detection of OTA in the complex matrix we made measurement of [39]. Our assay needs to improve the sensitivity for real sample analysis.…”
Section: Specificity Of Fluorescent Sensing Otamentioning
confidence: 99%
“…The results show the response of the fluorescent aptamer is specific for OTA. To further assess whether this method can be applied to the detection of OTA in the complex matrix we made measurement of [39]. Our assay needs to improve the sensitivity for real sample analysis.…”
Section: Specificity Of Fluorescent Sensing Otamentioning
confidence: 99%
“…Toxicology studies show that OTA has nephrotoxicity, hepatic and immune toxicity, and can cause teratogenic effects to a wide variety of mammalian species (Duarte et al, 2004;Lühe et al, 2003). Currently, the most widely applied methods for OTA detection rely on chromatographic approaches (Tessini et al, 2010) and immunoassays (Meulenberg, 2012). Particularly, thin-layer chromatography (TLC) (Pittet and Royer, 2002), high performance liquid chromatography (HPLC) (Ghali et al, 2008) and enzyme-linked immunosorbent assay (ELISA) (Liu et al, 2008) are recommended by the Association of Official Agricultural Chemists and European Commission.…”
Section: Introductionmentioning
confidence: 99%
“…126,127 From its development, IAC 128 has been applied and it is now widely used as a fundamental cleanup step prior to LC-FLD analysis or ELISA, showing higher recoveries and lower detection limits in comparison to SPE columns, 129 although a recent comparison showed that both methods are suitable for OTA analysis in wines. 130 Also, Mycosep and Multisep columns were successfully employed in this field. 131 A combined anion-exchange/reversedphase cleanup was proposed as a cost-effective alternative to IAC, but superior to simple reversed-phase cleanup as it allows elimination of neutral, acidic, and basic impurities.…”
Section: Winementioning
confidence: 99%