2001
DOI: 10.1093/clinchem/47.12.2183
|View full text |Cite
|
Sign up to set email alerts
|

Aminoglycoside Interference with the Dade Behring Pyrogallol Red–Molybdate Method for the Measurement of Total Urine Protein

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…At the end of the study period, urine was collected for 24 h from each rat to be subjected to determination of protein according to Koerbin et al [22] and creatinine according to Larsen [23] with calculation of creatinine clearance. Blood was withdrawn from each rat to be subjected to determination of plasma levels of creatinine [23] and urea [24] in addition to the activities of lactate dehydrogenase (LDH) according to Zimmerman and Weinstein [25], aspartate transaminase (AST) and alanine transaminase (ALT) according to Reitman and Frankel [26], alkaline phosphatase (ALP) according to Bessey et al [27] and Gama-GT (γ- GT) according to [28] as well as the levels of total protein and albumin according to Rheinhold [29] and Doumas et al [30] in succession with calculation of globulin and albumin/globulin (A/G) ratio.…”
Section: Methodsmentioning
confidence: 99%
“…At the end of the study period, urine was collected for 24 h from each rat to be subjected to determination of protein according to Koerbin et al [22] and creatinine according to Larsen [23] with calculation of creatinine clearance. Blood was withdrawn from each rat to be subjected to determination of plasma levels of creatinine [23] and urea [24] in addition to the activities of lactate dehydrogenase (LDH) according to Zimmerman and Weinstein [25], aspartate transaminase (AST) and alanine transaminase (ALT) according to Reitman and Frankel [26], alkaline phosphatase (ALP) according to Bessey et al [27] and Gama-GT (γ- GT) according to [28] as well as the levels of total protein and albumin according to Rheinhold [29] and Doumas et al [30] in succession with calculation of globulin and albumin/globulin (A/G) ratio.…”
Section: Methodsmentioning
confidence: 99%
“…There are findings that aminoglycoside antibiotics, including gentamicin, can interfere with this assay, but also in urine samples. 37,38 Likewise, most of the tested parameters can be measured in plasma samples, so it would be useful to test this as well. Advantages of plasma are that it enables laboratories to achieve faster turnaround time and it is a preferred sample for point-of-care testing.…”
Section: Discussionmentioning
confidence: 99%