2009
DOI: 10.1002/elan.200804586
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric Ethanol Biosensor Based on Integration of Alcohol Dehydrogenase with Meldola's Blue/Ordered Mesoporous Carbon Electrode

Abstract: An amperometric ethanol biosensor was fabricated by integration of alcohol dehydrogenase (ADH) with meldolas blue (MB)/ordered mesoporous carbon (OMC) composite modified glassy carbon electrode (MB/OMC/GCE). The MB/OMC/GCE was highly sensitive for nicotinamide adenine dinucleotide (NADH) measurement (9.1 AE 0.25 mA/ mM) and gave a low detection limit of 0.21 AE 0.02 mM. The ethanol biosensor exhibited a wide linear range up to 6 mM with a lower detection limit of 19.1 AE 0.58 mM as well as a high sensitivity o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
25
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(26 citation statements)
references
References 39 publications
(25 reference statements)
1
25
0
Order By: Relevance
“…These fied electrode [48], 10 mM, 25 mM to 1 mM for titanium containing MCM-41 modified glassy carbon electrode [49] and 19 mM, 34.58 nA mM À1 with linear range up to 6 mM for meldolas blue ordered mesoporous carbon composite modified glassy carbon electrode [50]. These data confirm the efficiency of both, CPZ oxidation product as an electron transfer mediator, and IL-CNTs an nanocomposite for immobilization of enzyme and redox mediator.…”
Section: Differential Pulse Voltammetric Biosensing Of Ethanolsupporting
confidence: 73%
“…These fied electrode [48], 10 mM, 25 mM to 1 mM for titanium containing MCM-41 modified glassy carbon electrode [49] and 19 mM, 34.58 nA mM À1 with linear range up to 6 mM for meldolas blue ordered mesoporous carbon composite modified glassy carbon electrode [50]. These data confirm the efficiency of both, CPZ oxidation product as an electron transfer mediator, and IL-CNTs an nanocomposite for immobilization of enzyme and redox mediator.…”
Section: Differential Pulse Voltammetric Biosensing Of Ethanolsupporting
confidence: 73%
“…The same enzyme was immobilized on the surface of electrode and used in that form for preparative purposes (Somers et al, 1998). Although another type of alcohol dehydrogenases were used for biosensor design (Jiang et al 2009) Quinohaemoprotein alcohol dehydrogenase as yet didn't find any analytical application.…”
Section: Chiral Catalysismentioning
confidence: 99%
“…[4][5][6][7]. OMC is also a promising EM wave-absorbing materials closely related to its ordered microstructure [8].…”
Section: Introductionmentioning
confidence: 99%