2018
DOI: 10.1109/tie.2017.2726992
|View full text |Cite
|
Sign up to set email alerts
|

An Adaptive Digital-Control Scheme for Improved Active Power Filtering Under Distorted Grid Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(33 citation statements)
references
References 30 publications
0
33
0
Order By: Relevance
“…An input voltage peak detector is used to approximate the value of v P CC,1 to v P CC,1 ≈ V P CC,peak sin(ωt). Different approaches, such as the zero-phase detector circuit in [53] or PLLs can be applied here, the last one being the preferred approach to achieve immunity to input voltage distortion [54], [55], as is included in certain PFC proposals [56], [57]. Hence, (30) is rewritten as…”
Section: Implementation Of the Pqe Controllermentioning
confidence: 99%
“…An input voltage peak detector is used to approximate the value of v P CC,1 to v P CC,1 ≈ V P CC,peak sin(ωt). Different approaches, such as the zero-phase detector circuit in [53] or PLLs can be applied here, the last one being the preferred approach to achieve immunity to input voltage distortion [54], [55], as is included in certain PFC proposals [56], [57]. Hence, (30) is rewritten as…”
Section: Implementation Of the Pqe Controllermentioning
confidence: 99%
“…• 100 (30) where the V − o rms is the rms values of the negative of the DG output voltage and the V + o rms is the rms values of the positive of the DG output voltage.…”
Section: Voltage Compensationmentioning
confidence: 99%
“…Several studies, such as References [27][28][29][30][31][32] have proposed to use the APFs and UPQC for the cancellation of the voltage and current harmonics in MG. Along this line, Cheng et al [27] proposed a control strategy using distributed APFs to weaken the voltage harmonics of the system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, to ensure a negligible frequency deviation during the discretization of the PR controller transfer function through the bilinear transformation, this scheme uses the relatively high switching frequency of 20 kHz. To improve the estimation performance of the grid phase and frequency in the presence of voltage harmonics, the study in reference [14] proposed an adaptive digital control scheme for three-phase active power filtering comprising an enhanced SRF phase-locked loop (PLL). This research work demonstrates the improvement in grid phase and frequency estimation as well as in current control performance under adverse grid conditions by means of the online updating of resonance parameters.…”
Section: Introductionmentioning
confidence: 99%