Abstract:The mathematical modeling is performed of the efficiency of flue gas cleaning from fly ash particles of coal-fired thermal power plants, upon installation of a preliminary flue gas cleaning system that consists of a louvered dust concentrator and a battery cyclone, with the recirculation of flue gas from the battery cyclone outlet to the electrostatic precipitator pre-chamber. Based on the available experimental data for the fractional composition of fly ash downstream the boilers of coal-fired TPPs, the size … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.