2022
DOI: 10.1039/d2lc00012a
|View full text |Cite
|
Sign up to set email alerts
|

An antibiotic concentration gradient microfluidic device integrating surface-enhanced Raman spectroscopy for multiplex antimicrobial susceptibility testing

Abstract: Antimicrobial susceptibility testing (AST) are a key measure in clinical microbiology laboratories to enable appropriate antimicrobial administration. During an AST, the determination of the minimum inhibitory concentration (MIC) is an...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(19 citation statements)
references
References 35 publications
1
18
0
Order By: Relevance
“…Lin et al developed microfluidic devices integrating SERS for antimicrobial susceptibility testing . The more recent version of the devices was designed to load and confine bacteria into an array of microwells and generate a concentration gradient of the antibiotics within the wells for multiparallel testing of the minimum inhibitory concentration . After bacteria incubation in varying concentrations of the antibiotics, the top layer of the device was replaced with a SERS substrate to measure SERS signals of bacterial metabolites.…”
Section: Sensor and Detection Technologymentioning
confidence: 99%
“…Lin et al developed microfluidic devices integrating SERS for antimicrobial susceptibility testing . The more recent version of the devices was designed to load and confine bacteria into an array of microwells and generate a concentration gradient of the antibiotics within the wells for multiparallel testing of the minimum inhibitory concentration . After bacteria incubation in varying concentrations of the antibiotics, the top layer of the device was replaced with a SERS substrate to measure SERS signals of bacterial metabolites.…”
Section: Sensor and Detection Technologymentioning
confidence: 99%
“…SERS-based AST can eliminate the need for overnight culture and reduce the testing time, as it can rapidly assess the response and the susceptibility of bacteria to the antibiotic treatments. 83–85 In turn, this will be helpful in understanding the mechanism of action and effectiveness of antibiotics in a short time and allow a rapid decision to be taken by the physicians. 86…”
Section: Sers For Antibiotic Resistance Diagnosismentioning
confidence: 99%
“…To stabilize subjects, for example, cells in the middle observation chamber, the low-height channel [ 17 , 18 ], the membrane [ 19 ] and gels [ 20 , 21 ] were employed to form the obstacles. The unique advantage of high integration makes it possible for microfluidics to contain an array of chambers for high-through gradient analysis using limited samples [ 22 , 23 , 24 , 25 ]. However, the self-diffusion-based approach can only maintain a simple gradually decreasing concentration between a chemical source and a sink channel.…”
Section: Introductionmentioning
confidence: 99%