2015
DOI: 10.1016/j.bbapap.2014.10.008
|View full text |Cite
|
Sign up to set email alerts
|

An automated assay for the clinical measurement of plasma renin activity by immuno-MALDI (iMALDI)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
27
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(28 citation statements)
references
References 36 publications
1
27
0
Order By: Relevance
“…Using the sensitivity of immunoaffinity capture combined with the specificity of mass spectrometry detection, he demonstrated results of plasma renin activity measurement, an established biomarker for primary aldosteronism [7].…”
Section: Proteomic Techniquesmentioning
confidence: 99%
“…Using the sensitivity of immunoaffinity capture combined with the specificity of mass spectrometry detection, he demonstrated results of plasma renin activity measurement, an established biomarker for primary aldosteronism [7].…”
Section: Proteomic Techniquesmentioning
confidence: 99%
“…Recently, iMALDI technology development has focused on automation (Fig. (a)), particularly for the measurement of plasma renin activity (PRA) as a screening method for primary aldosteronism (PA). Protein G Dynabeads with 2.8‐μm diameter were used for immuno‐enrichment.…”
Section: Mass Spectrometry‐based Assays With Antibody‐based Enrichmentmentioning
confidence: 99%
“…Protein G Dynabeads with 2.8‐μm diameter were used for immuno‐enrichment. The LLOD and linear range obtained met clinical requirements, and inter‐day CVs lower than 10% were obtained with an automated liquid handling system . The results of measuring patients' samples using iMALDI correlated well with those of clinically used LC–MS/MS assays and ELISA.…”
Section: Mass Spectrometry‐based Assays With Antibody‐based Enrichmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Two of the main advantages of MALDI-TOF-MS in comparison with classical LC-MS/MS are its high throughput and its cost effectiveness. This approach could also be used after using immunocapture methods to reduce the complexity of the samples[63,64].3.2. Electrospray ionization (ESI) triple quadrupole mass spectrometers: the MRM/SRM mode Multiple Reaction Monitoring (MRM) (or Selected Reaction Monitoring) methods are classically performed using a triple quadrupole (QqQ) mass spectrometer coupled with HighPerformance Liquid Chromatography (HPLC).…”
mentioning