IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society 2013
DOI: 10.1109/iecon.2013.6700152
|View full text |Cite
|
Sign up to set email alerts
|

An enhanced MMC topology with DC fault ride-through capability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 80 publications
(31 citation statements)
references
References 17 publications
0
31
0
Order By: Relevance
“…Commonly used half-bridge cells do not have dc side fault blocking capability, which complicates the development of large multi-terminal dc-grids [3]. In this regard, new cell topologies have been proposed, such as full-bridge cells or diode-clamp SubModules (SMs) [4], [5]. Other converter topologies have also been proposed to limit short-circuit currents [6], [7].…”
Section: Igh-voltage DC (Hvdc) Links With Linementioning
confidence: 99%
“…Commonly used half-bridge cells do not have dc side fault blocking capability, which complicates the development of large multi-terminal dc-grids [3]. In this regard, new cell topologies have been proposed, such as full-bridge cells or diode-clamp SubModules (SMs) [4], [5]. Other converter topologies have also been proposed to limit short-circuit currents [6], [7].…”
Section: Igh-voltage DC (Hvdc) Links With Linementioning
confidence: 99%
“…Among them, the subscripts p and n represent upper arm and lower arm respectively, and o is the neutral point. Reference direction is as shown in Figure 1 [19]. As shown in Figure 1, according to Kirchhoff current theory,…”
Section: Influence Of Ac Transient Faults On MMCmentioning
confidence: 99%
“…Therefore, z-transform of filter banks is expressed as follows. (19) where, G(z) is z-transform of high-pass filter, H(z) is z-transform of low-pass filter. For convenience, Equation (19) is transformed into recurrence relation as follows.…”
Section: Contrastanalysisof Rwpe and Swpementioning
confidence: 99%
“…The modulation and control strategies [19] of a new hybrid VSC with DC fault-tolerant capability called hybrid cascaded multilevel converter (HCMC) [18] are further studied. A new sub-module structure was also proposed [20]. A common disadvantage of these topologies is the need for massive power electronic devices that lead to higher costs.…”
Section: Introductionmentioning
confidence: 99%