2020
DOI: 10.1016/j.talanta.2020.121377
|View full text |Cite
|
Sign up to set email alerts
|

An europium functionalized carbon dot-based fluorescence test paper for visual and quantitative point-of-care testing of anthrax biomarker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 56 publications
(25 citation statements)
references
References 49 publications
0
25
0
Order By: Relevance
“…The fluorescent lateral flow assay owned good reproducibility, high specificity and sensitivity due to the excellent fluorescent properties of CSNs, and was able to achieve a low visual detection limit of as low as 10 pg mL −1 SFTSV nucleoprotein which was 2 orders of magnitude higher than that of the colloidal gold-based lateral flow test strip. Most recently, Wang et al [151] developed a Eu(III) functionalized carbon dots (CDs-Eu)-based ratiometric fluorescent test paper for sensitive POC detection of dipicolinic acid (DPA), a biomarker of anthrax. This ratiometric fluorescent test paper exhibited excellent detection performance with high sensitivity which could achieve a linearity range from 0.5 nM to 5 μM and a detection limit of 0.8 nM.…”
Section: Detection Methods For Poc Diagnostic Applicationsmentioning
confidence: 99%
“…The fluorescent lateral flow assay owned good reproducibility, high specificity and sensitivity due to the excellent fluorescent properties of CSNs, and was able to achieve a low visual detection limit of as low as 10 pg mL −1 SFTSV nucleoprotein which was 2 orders of magnitude higher than that of the colloidal gold-based lateral flow test strip. Most recently, Wang et al [151] developed a Eu(III) functionalized carbon dots (CDs-Eu)-based ratiometric fluorescent test paper for sensitive POC detection of dipicolinic acid (DPA), a biomarker of anthrax. This ratiometric fluorescent test paper exhibited excellent detection performance with high sensitivity which could achieve a linearity range from 0.5 nM to 5 μM and a detection limit of 0.8 nM.…”
Section: Detection Methods For Poc Diagnostic Applicationsmentioning
confidence: 99%
“…The most important thing is that the output signal of POCT is very simple and easy to get, usually including color, distance, pressure, temperature, etc. [131][132][133][134][135].…”
Section: Detection Methods Based On Point-of-care Testing (Poct)mentioning
confidence: 99%
“…Recently, Wang et al also used a smart phone, to determine anthrax based on color change, using Eu(III) functionalized carbon dots (CDs-Eu) as a fluorescent probe, where DPA (an anthrax biomarker) can interact with CDs-Eu, resulting in a color change. Using the color analysis software on the smartphone, DPA can be quantified, and its linear range is 0.5 nM to 5 µM with a LOD of 0.8 nM ( Figure 6D) [131]. Xiao et al designed an optical microfiber sensor modified by a polystyrene@gold nanosphere to detect the (CEA)-related cell adhesion molecules 5 (CEACAM5) concentration in serum.…”
Section: Poct Based Detection Of Enzyme Activity/proteins/compoundmentioning
confidence: 99%
See 1 more Smart Citation
“…Anthracnosis is a zoonotic, severe infectious disease caused by Bacillus anthrax, in which spores may be transmitted by food, water and air. [1][2][3][4][5][6][7] The inhalation of 10 4 Bacillus anthracis spores is deadly without treatment within 24-48 hours. [8][9][10] Anthrax has a microstructure that is highly resistant to extreme environments and can resist environments such as high temperature and high pressure, drought, ultraviolet irradiation, chemical disinfectants, strong acids and alkalis.…”
Section: Introductionmentioning
confidence: 99%