2021
DOI: 10.1016/j.renene.2021.07.145
|View full text |Cite
|
Sign up to set email alerts
|

An experimental investigation on thermal and optical analysis of cylindrical and conical cavity copper tube receivers design for solar dish concentrator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 50 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…As shown in Figure 2A by comparing the electrical power predicted by the theoretical model of the photovoltaic‐thermal module with experimental results reported by Abdul‐Ganiyu et al, 55 it was found that the tolerances are within ±3.5%. Figure 2B makes a comparison between the results of the hot water temperature of the current model and the work by Hassan et al 56 for the solar dish concentrator with the solar thermal receiver; it was found that the tolerances are within ±4.9%. Also, by comparing the yield of pure water predicted by the model of the HDH unit with experimental results reported by Nada et al, 57 it was found that the tolerances are within ±4.7%.…”
Section: Model Validationmentioning
confidence: 68%
See 3 more Smart Citations
“…As shown in Figure 2A by comparing the electrical power predicted by the theoretical model of the photovoltaic‐thermal module with experimental results reported by Abdul‐Ganiyu et al, 55 it was found that the tolerances are within ±3.5%. Figure 2B makes a comparison between the results of the hot water temperature of the current model and the work by Hassan et al 56 for the solar dish concentrator with the solar thermal receiver; it was found that the tolerances are within ±4.9%. Also, by comparing the yield of pure water predicted by the model of the HDH unit with experimental results reported by Nada et al, 57 it was found that the tolerances are within ±4.7%.…”
Section: Model Validationmentioning
confidence: 68%
“…The input parameters of the incorporated mathematical models used to solve the four integrated theoretical models proposed in the current study are presented in Table 1. These geometrical details and thermal and optical properties of the different components of this hybrid system have been also described in the studies done by 39,45‐47,49‐56 …”
Section: Mathematical Modelingmentioning
confidence: 86%
See 2 more Smart Citations
“…Hassan et al 89 numerically investigated the performance of cylindrical and conical type cavity tube receivers with water as HTF using COMSOL software. The thermal and exergetic efficiency of the conical receiver was better than the cylindrical receiver.…”
Section: Cavity Receiversmentioning
confidence: 99%