2018
DOI: 10.1016/j.applthermaleng.2018.06.053
|View full text |Cite
|
Sign up to set email alerts
|

An experimental study of an anti-gravity vapor chamber with a tree-shaped evaporator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(16 citation statements)
references
References 24 publications
0
16
0
Order By: Relevance
“…Yao et al [30] developed a vapor chamber characterized by a tree-shaped groove wick and a screen mesh wick that fills the vapor area. Their vapor chamber showed better performance in the top heating mode with mesh wicks, and with very small increases in thermal resistances.…”
Section: Introductionmentioning
confidence: 99%
“…Yao et al [30] developed a vapor chamber characterized by a tree-shaped groove wick and a screen mesh wick that fills the vapor area. Their vapor chamber showed better performance in the top heating mode with mesh wicks, and with very small increases in thermal resistances.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the wick structure for the condenser combines the fractal network microchannels and copper foam, which are used to imitate the macroscopic leaf vein network and microscopic mesophyll tissue, respectively, which are also higher than most existing vapor chambers (Luo et al, 2020). To obtain better performance, the smaller size powder, reducing the diameter and spacing of the support columns (Huang et al, 2020;Liu et al, 2018), with a mini channel with a wick layer (Wiriyasart and Naphon, 2018b), micro/nanostructured evaporator (Sun and Qiu, 2014), grooves, and hybrid mesh wick (Yao et al, 2018), hybrid wick Constant Conductance Heat Pipes (CCHPs) (Ababneh et al, 2015), much lower than that of vapor chamber with bare sintered wick by enhanced both the critical heat flux (CHF) and heat transfer coefficient (HTC) to solve the high heat flux limitation for future highly integrated electronics. Also, the configuration of the evaporator wick porosity should be slightly larger than the condenser wick porosity to provide the maximum pressure drop in the wicks and slightly less than the maximum capillary pressure .…”
Section: Introductionmentioning
confidence: 99%
“…At present, electronic devices tend to be miniaturized and compact [1,2]. Therefore, the power density of electronic devices is increasing [3]. In order to meet the heat dissipation requirements, the cooling equipment must be efficient and flexible enough [4].…”
Section: Introductionmentioning
confidence: 99%
“…It is a special form of flat heat pipe [5], and is often used for thermal management of electronic devices [6]. The vapor chamber is composed of shell, wick, and steam chamber [3]. There is working fluid inside the vapor chamber.…”
Section: Introductionmentioning
confidence: 99%