An experimental study on the effect of frame-to-wall connection type on the seismic behavior of steel frames infilled with autoclave-cured aerated concrete blocks

Abstract: In this article, in order to find some reliable connection types for avoiding the infill failure, an experimental study is conducted on six half-scale single-story single-bay specimens, including one bare frame and five steel frames with autoclave-cured aerated concrete walls, each having different frame-to-wall connection types. Polyurethane adhesive was used in bed joints of the autoclave-cured aerated concrete walls as a mortar. The specimens were tested under displacement-controlled loading to examine thei… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…Similarly, Saheb et al conducted experiments on single-layer, single-span specimens and performed performance analysis to enhance the connection method between frame and infill walls, achieving effective filling. The research method ensured intact filling with positive application effects [8]. Davorin et al focused on investigating the role of masonry infill walls in the shear bearing capacity of frames, particularly examining the impact of different types of openings on individual component performance.…”
Section: Related Workmentioning
confidence: 99%
“…Similarly, Saheb et al conducted experiments on single-layer, single-span specimens and performed performance analysis to enhance the connection method between frame and infill walls, achieving effective filling. The research method ensured intact filling with positive application effects [8]. Davorin et al focused on investigating the role of masonry infill walls in the shear bearing capacity of frames, particularly examining the impact of different types of openings on individual component performance.…”
Section: Related Workmentioning
confidence: 99%
“…Saheb Ali Asadzadeh et al [16], conducted proposed static tests of steel frames for 6-bay masonry infill walls and proposed five different flexible connectors, which were shown to be Vshaped (Fig. 2) and T-type (Fig.…”
Section: Experimental Study On Seismic Performance Of Infill Wall Fra...mentioning
confidence: 99%
“…The favorable materials for the flexible joints in the separation gaps include the rigidbrittle element, 16 perforated autoclaved aerated concrete block, 17 cellular polyethylene plate, 5 Styrofoam, 18 polyurethane foam, 19 U-shaped elastomer, 20 cellular material, 21 deformable matrix material, 22 grooved lead, 23 stone wools, 24 and steel connectors. 25 Notably, the key issue of this method is to prevent the reactivation of the multiple diagonal struts mechanism that would damage both the infills and frames.…”
Section: Introductionmentioning
confidence: 99%
“…To eliminate the adverse multiple diagonal struts effect of the infill walls, the idea of the next method is to uncouple the infill from the primary structure by cutting off the corner of the wall panels 15 or application of flexible joints around the wall‐frame interfaces. The favorable materials for the flexible joints in the separation gaps include the rigid‐brittle element, 16 perforated autoclaved aerated concrete block, 17 cellular polyethylene plate, 5 Styrofoam, 18 polyurethane foam, 19 U‐shaped elastomer, 20 cellular material, 21 deformable matrix material, 22 grooved lead, 23 stone wools, 24 and steel connectors 25 . Notably, the key issue of this method is to prevent the reactivation of the multiple diagonal struts mechanism that would damage both the infills and frames.…”
Section: Introductionmentioning
confidence: 99%