2022
DOI: 10.3390/s22041563
|View full text |Cite
|
Sign up to set email alerts
|

An Impedance Readout IC with Ratio-Based Measurement Techniques for Electrical Impedance Spectroscopy

Abstract: This paper presents an error-tolerant and power-efficient impedance measurement scheme for bioimpedance acquisition. The proposed architecture measures the magnitude and the real part of the target complex impedance, unlike other impedance measurement architectures measuring either the real/imaginary components or the magnitude and phase. The phase information of the target impedance is obtained by using the ratio between the magnitude and the real components. This can allow for avoiding direct phase measureme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 40 publications
0
10
0
Order By: Relevance
“…For the measurement aspect, Cheon et al presented an effective impedance measurement feature for bioimpedance consideration, where it measures the magnitude and the real part of the complex impedance [ 68 ]. Figure 25 shows the presented electrochemical impedance spectroscopy system, which measures the impedance over the targeted frequency band.…”
Section: Biomedical Applications From the Measurement Perspectivementioning
confidence: 99%
See 1 more Smart Citation
“…For the measurement aspect, Cheon et al presented an effective impedance measurement feature for bioimpedance consideration, where it measures the magnitude and the real part of the complex impedance [ 68 ]. Figure 25 shows the presented electrochemical impedance spectroscopy system, which measures the impedance over the targeted frequency band.…”
Section: Biomedical Applications From the Measurement Perspectivementioning
confidence: 99%
“… General structure of electrochemical impedance spectroscopy presented in [ 68 ] with a combination of voltage-controlled current source (VCCS), integrated circuit (IC), and instrumentation amplifier (IA). …”
Section: Figurementioning
confidence: 99%
“…The ASIC configuration has been applied in detecting DNA hybridization [23] and measuring bioimpedance, which could be achieved with low power consumption [24]. Furthermore, ASIC configurations have been reported for EIT when impedance with multiple channels is required, such as prostate cancer screening [25], lung imaging [26,27], and many other purposes [28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%
“…1. These approaches prioritize the accuracy and low-power consumption, potentially sacrificing the throughput and dynamic range, which are less important for the specific applications [16].…”
mentioning
confidence: 99%