An improved and fast UHPLC-PDA methodology for determination of L-ascorbic and dehydroascorbic acids in fruits and vegetables. Evaluation of degradation rate during storage

Abstract: This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultrahigh-performance liquid chromatographic-photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
68
0
3

Year Published

2012
2012
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 94 publications
(73 citation statements)
references
References 32 publications
2
68
0
3
Order By: Relevance
“…In the second approach to determine linearity, Figure 3B illustrates the relationship between the peak absorbance area and concentration for the L-AA standards. The results indicate that good linearity (r 2 =0.999) was observed from 5 to 200 µg/mL for the L-AA standards and is comparable to those obtained in other studies employing HPLC to measure L-AA in food products [18,23,25], however, at high concentrations (>200 µg/mL) poor linearity was observed. The poor linearity observed at high concentrations (>200 µg/mL) may be as a result of saturation of the detector [33].…”
Section: Methods Performance Parameterssupporting
confidence: 86%
See 2 more Smart Citations
“…In the second approach to determine linearity, Figure 3B illustrates the relationship between the peak absorbance area and concentration for the L-AA standards. The results indicate that good linearity (r 2 =0.999) was observed from 5 to 200 µg/mL for the L-AA standards and is comparable to those obtained in other studies employing HPLC to measure L-AA in food products [18,23,25], however, at high concentrations (>200 µg/mL) poor linearity was observed. The poor linearity observed at high concentrations (>200 µg/mL) may be as a result of saturation of the detector [33].…”
Section: Methods Performance Parameterssupporting
confidence: 86%
“…These results can be compared to those obtained by Kumar et al [35] who validated various levels of precision (COV's less than 2%) of an HPLC method for ascorbic acid determination in health drinks. Similarly, Spinola et al [23] obtained COV's within 4% for an improved HPLC method for the measurement of L-AA in various fruit and vegetables. In another study, using food commodities to measure ascorbic acid content by HPLC, the average COV obtained was 8.7% and is comparable to those obtained in the present study [36].…”
Section: Methods Performance Parametersmentioning
confidence: 84%
See 1 more Smart Citation
“…Vitamin C content was determined according to a method described by Spinola et al (2012) with modifications. Dried and powdered broccoli samples (0.5 g) were extracted in 5% metaphosphoric acid solution.…”
Section: Vitamin C Analysismentioning
confidence: 99%
“…High performance liquid chromatographic (HPLC) methods have been widely applied in the analysis of vitamin C in various foods (e.g. Barros et al, 2010;Brause et al, 2003;Davey et al, 2003;Drivelos et al, 2010;Garrido-Frenich et al, 2005;Gokmen et al, 2000;Hernadez et al, 2006;Laur and Tian, 2011;Lee and Coates, 1999;Lykkesfeldt, 2000;Nishiyama et al, 2004;Novakova et al, 2008a;OdriozolaSerrano et al, 2007;Romeu-Nadal et al, 2006;Spínola et al, 2012;Wechtersbach and Cigic, 2007), but currently there is no standard method for the analysis of vitamin C in different food matrices.…”
Section: Introductionmentioning