2004
DOI: 10.1109/tie.2003.822091
|View full text |Cite
|
Sign up to set email alerts
|

An Improved ZCT-PWM DC–DC Converter for High-Power and Frequency Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(24 citation statements)
references
References 13 publications
0
24
0
Order By: Relevance
“…In some of the previously proposed bidirectional converters [2]- [6] two auxiliary circuits are employed to achieve soft switching when the power flows in both directions ( Fig. 1.9).…”
Section: Soft-switching In Pwm Bidirectional Dc-dc Convertersmentioning
confidence: 99%
“…In some of the previously proposed bidirectional converters [2]- [6] two auxiliary circuits are employed to achieve soft switching when the power flows in both directions ( Fig. 1.9).…”
Section: Soft-switching In Pwm Bidirectional Dc-dc Convertersmentioning
confidence: 99%
“…High switching frequency operation, however, results in higher switching losses, increased electromagnetic interference (EMI), and reduced converter efficiency. Numerous soft-switching techniques have been proposed to correct these problems [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17]. Almost all these techniques achieve soft switching condition in the main switch using an active auxiliary circuit.…”
Section: Introductionmentioning
confidence: 99%
“…In order to improving these problems in converters, zero-voltage transition (ZVT) and zero-current transition (ZCT) converters are developed [13][14][15][16]. ZVT and ZCT converters have the advantages of resonant and quasi-resonant converters like low EMI, and the resonances are limited with switching instances, and therefore the converter operates like a regular PWM converter, but in these converters, an auxiliary circuit containing resonant elements and auxiliary switches are used, and need complexity control system.…”
Section: Introductionmentioning
confidence: 99%
“…To alleviate these problems, significant derating of device voltage and current ratings and elaborate passive snubbers are usually used, and the switching frequency is limited to low-frequency ranges. Generally, a snubber circuit reduces the switching loss and switching stresses of switches, however, increases the total power loss in the converter [4,5].…”
Section: Introductionmentioning
confidence: 99%
“…However, they have still additional current stress on the main switch [3, 4, 8, 9, 13 -15]. Similarly, the auxiliary switch turns on hard in the converter in [12], and the auxilary switch turns off partial hard and has an additional voltage stress in the converter in [3,4,9]. The total time of the transient periods is long in the circuits in [1,3,4,6,15].…”
Section: Introductionmentioning
confidence: 99%