2016
DOI: 10.1557/adv.2016.334
|View full text |Cite
|
Sign up to set email alerts
|

An In Situ Transmission Electron Microscopy Study of Localized Corrosion on Aluminum

Abstract: While the growth of pits in passive metals exposed to chloride solutions is well understood, the processes associated with the initiation and propagation of stable pits, versus pits that form and apparently re-passivate, are still a matter of conjecture. A major challenge in studying pit initiation using electron microscopy has been alteration of the structure and chemistry of the hydrated corrosion films upon transfer to the vacuum environment of the microscope. A recently developed technique uses a microflui… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 16 publications
0
1
0
Order By: Relevance
“…The main advantage of using NRs with thin silicon nitride electron transparent windows (with a thickness of 50 nm or less) is that corrosion studies can be done in the presence of corrosive conditions on the nonconductive substrate. In addition, for most corrosion studies, it is necessary to apply potentials or currents (to initiate anodic or cathodic reactions) which requires the presence of electrodes in the NR (de Jonge & Ross, 2011; de Jonge et al, 2019), and recently (Wee Chee et al, 2014; Chee et al, 2015; Hun Park et al, 2015; Pinkowitz et al, 2016) it is used an NR with SiN membranes and an electrode for corrosion studies. The dynamics of corrosion from initiation to corrosion damage was analyzed at a relatively good resolution on thin film deposited metals, confirming results reported in postmortem TEM studies (e.g., in aqueous solutions).…”
Section: Introductionmentioning
confidence: 99%
“…The main advantage of using NRs with thin silicon nitride electron transparent windows (with a thickness of 50 nm or less) is that corrosion studies can be done in the presence of corrosive conditions on the nonconductive substrate. In addition, for most corrosion studies, it is necessary to apply potentials or currents (to initiate anodic or cathodic reactions) which requires the presence of electrodes in the NR (de Jonge & Ross, 2011; de Jonge et al, 2019), and recently (Wee Chee et al, 2014; Chee et al, 2015; Hun Park et al, 2015; Pinkowitz et al, 2016) it is used an NR with SiN membranes and an electrode for corrosion studies. The dynamics of corrosion from initiation to corrosion damage was analyzed at a relatively good resolution on thin film deposited metals, confirming results reported in postmortem TEM studies (e.g., in aqueous solutions).…”
Section: Introductionmentioning
confidence: 99%