2018
DOI: 10.1016/j.tust.2017.08.002
|View full text |Cite
|
Sign up to set email alerts
|

An in-tunnel grouting protection method for excavating twin tunnels beneath an existing tunnel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
34
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 111 publications
(35 citation statements)
references
References 11 publications
1
34
0
Order By: Relevance
“…The maximum offset of the CWO sewer is pushed in the diagonal axis which is detected when the tunnel face advancement is ahead of the point A by approximately 24 m or 39 m behind the tunnel. The observed trend of the CWO deformation matched with the documented by Jin, Yuan, Li and Zheng (2018).…”
Section: Cwo Sewer Settlementsupporting
confidence: 86%
See 1 more Smart Citation
“…The maximum offset of the CWO sewer is pushed in the diagonal axis which is detected when the tunnel face advancement is ahead of the point A by approximately 24 m or 39 m behind the tunnel. The observed trend of the CWO deformation matched with the documented by Jin, Yuan, Li and Zheng (2018).…”
Section: Cwo Sewer Settlementsupporting
confidence: 86%
“…The construction of two closely distant tunnels under an existing tunnel can cause greater deformation for the existing tunnel and the ground due to the dual disturbances caused by the tunneling process (Jin, Yuan, Li & Zheng, 2018). Several studies have estimated the ground movements as well as the deformation has induced in the existing tunnels by the construction of a new tunnel (Fang, Zhang, Li & Wong, 2015;Zhang, Liu, Kang, Zhong & Chen, 2018;Lin, Chen, Wu & Cheng, 2019).…”
Section: Introductionmentioning
confidence: 99%
“…Employing PLAXS software numerical analysis, Vinod and Khabbaz [8] studied the surface settlements and bending moments of circular and rectangular twin tunnel linings, where the key research parameters included the relative position, critical distance, volume loss, overburden, and size of the twin tunnel.…”
Section: Introductionmentioning
confidence: 99%
“…Jin et al [7] found that in an existing tunnel using double-tunnel grouting protection method, a tunnel grouting method, and combining with shield method, can effectively reduce the double underground tunnel construction influence on existing tunnel and on the settlement and stress of the tunnel monitoring system, but the scope of this method is limited and can be applied only to tunnel grouting. Ping et al [8] proposed a leakage plugging method with low-heat asphalt grouting, whose construction temperature is less than 80°C.…”
Section: Introductionmentioning
confidence: 99%