2022
DOI: 10.1109/tpwrd.2022.3173431
|View full text |Cite
|
Sign up to set email alerts
|

An Inrush Current Suppression Strategy for UHV Converter Transformer Based on Simulation of Magnetic Bias

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(1 citation statement)
references
References 9 publications
0
1
0
Order By: Relevance
“…From the aforementioned analysis, it can be observed that by changing the closing angle, the closing overcurrent multiplier can be reduced, and when the closing angle is 90 °, the closing overcurrent multiplier reaches the minimum, but the harmonic distortion rate increases. However, the method of changing the closing angle can only reduce the overcurrent multiplier of one or two phases because the essence of changing the closing angle is equivalent to shifting the threephase voltage and current by an angle, and the calculation results also show that when the closing overcurrent multiplier of phase A decreases, the closing overcurrent multiplier of phases B and C Series closing resistance method Hang et al (2022) proposed a method to reduce the overcurrent multiplier by connecting the closing resistors in series. Therefore, some simulations were carried out by stringing in resistors of different resistance values in the simulation platform, and the results are shown in Table 6.…”
Section: Adjustment Of the Closing Angle Methodsmentioning
confidence: 99%
“…From the aforementioned analysis, it can be observed that by changing the closing angle, the closing overcurrent multiplier can be reduced, and when the closing angle is 90 °, the closing overcurrent multiplier reaches the minimum, but the harmonic distortion rate increases. However, the method of changing the closing angle can only reduce the overcurrent multiplier of one or two phases because the essence of changing the closing angle is equivalent to shifting the threephase voltage and current by an angle, and the calculation results also show that when the closing overcurrent multiplier of phase A decreases, the closing overcurrent multiplier of phases B and C Series closing resistance method Hang et al (2022) proposed a method to reduce the overcurrent multiplier by connecting the closing resistors in series. Therefore, some simulations were carried out by stringing in resistors of different resistance values in the simulation platform, and the results are shown in Table 6.…”
Section: Adjustment Of the Closing Angle Methodsmentioning
confidence: 99%