An Integrated Lab‐on‐a‐chip Approach to Study Heterogeneous Enantioselective Catalysts at the Microscale

Abstract: An integrated lab‐on‐a‐chip enables the rapid analysis of heterogenized enantioselective organocatalysis at the microscale. A packed‐bed microreactor was seamlessly integrated with a downstream chiral high pressure liquid chromatography (HPLC) functionality to study enantioselective transformations on a single microfluidic glass chip. Hyphenation to mass spectrometry allows for the rapid investigation of the selectivity and the substrate scope of microgram amounts of catalyst beads. Optimization of reaction co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
42
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

5
1

Authors

Journals

citations
Cited by 26 publications
(42 citation statements)
references
References 67 publications
0
42
0
Order By: Relevance
“…The latter can be realized by applying spectroscopic techniques, such as fluorescence or Raman microscopy, or by coupling microfluidic chips to mass spectrometry. For isomer discrimination, we previously reported the integration of microflow reactions and chip HPLC [7][8][9] that allowed for the analysis of enantioselective transformations.…”
Section: Electronic Supplementary Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…The latter can be realized by applying spectroscopic techniques, such as fluorescence or Raman microscopy, or by coupling microfluidic chips to mass spectrometry. For isomer discrimination, we previously reported the integration of microflow reactions and chip HPLC [7][8][9] that allowed for the analysis of enantioselective transformations.…”
Section: Electronic Supplementary Materialsmentioning
confidence: 99%
“…Microchip used in this study. b Layout of chip setup in front of IM spectrometer inlet with a side view of the microfluidic chip (1), the IM spectrometer inlet (2), the LED positioned in front of the chip reactor region (3), the LED cooler (4), the counter electrode (5), the laser beam (6), a PTFE insulation plate (7), the capillary system and microchip mount including clamps(8), and a fine positioning stage(9). c Inhouse-built IR-MALDI IM spectrometer with heated inlet in top view, inlet (2) at the bottom-left is equivalent to (2) of panel b, the pump inlet (10), the pulsed ion inlet (11), the drift tube(12), and the faraday plate (13) as the detection element…”
mentioning
confidence: 99%
“…Initially, the flow‐through behavior of the fabricated device was evaluated using the asymmetric α‐amination of aliphatic aldehyde 1 with dibenzyl azodicarboxylate (DBAD) 2 as the benchmark (Scheme ). This model reaction was performed under the conditions previously employed with the silica‐supported counterpart for a direct comparison . This on‐line HPLC/MS analysis revealed the formation of adduct 3 with a much higher enantiomeric excess (50 % vs. 6 % ee ).…”
Section: Figurementioning
confidence: 99%
“…This model reaction was performed under the conditions previously employed with the silica-supported counterpart for ad irect comparison. [55] Thiso n-line HPLC/MS analysisr evealed the formation of adduct 3 with a much higher enantiomeric excess (50 %v s. 6% ee). Furthermore, the low pressure drop of just 1bar at the applied flow rate of 0.2 mLmin À1 allows operating the setup with economic low pressure pumps.…”
mentioning
confidence: 99%
See 1 more Smart Citation