2005
DOI: 10.1016/j.jchromb.2005.07.015
|View full text |Cite
|
Sign up to set email alerts
|

An LC–MS–MS method for the determination of cyclizine in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 13 publications
1
10
0
Order By: Relevance
“…We were unable to locate any LC-MS/MS assays in the literature involving both cyclizine and norcyclizine. Cyclizine, but not norcyclizine, has been determined in human plasma by LC-MS/MS as reported by the Walker and Kanfer group [10], and an LC-MS/MS antihistamine screening assay, which includes cyclizine, has been described [11]. As no existing methods were suitable for our purposes, the aim of the current work was to develop and validate a rapid and simple LC-MS/MS assay for simultaneous determination of cyclizine and norcyclizine concentrations in human plasma to be used for a clinical study.…”
Section: Introductionmentioning
confidence: 86%
See 2 more Smart Citations
“…We were unable to locate any LC-MS/MS assays in the literature involving both cyclizine and norcyclizine. Cyclizine, but not norcyclizine, has been determined in human plasma by LC-MS/MS as reported by the Walker and Kanfer group [10], and an LC-MS/MS antihistamine screening assay, which includes cyclizine, has been described [11]. As no existing methods were suitable for our purposes, the aim of the current work was to develop and validate a rapid and simple LC-MS/MS assay for simultaneous determination of cyclizine and norcyclizine concentrations in human plasma to be used for a clinical study.…”
Section: Introductionmentioning
confidence: 86%
“…2). Positive mode ionisation and the MRM transition 267/167 for cyclizine have also been used in the two previously reported LC-MS/MS assays for cyclizine [10,11].…”
Section: Assay Developmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The method was validated with respect to parameters including linearity, limit of quantitation (LOQ), limit of detection (LOD), precision, accuracy, ruggedness/robustness, recovery and selectivity (Mohammadi, Kanfer, Sewram, & Walker, 2005;Mohammadi et al, 2007).…”
Section: Validationmentioning
confidence: 99%
“…1,2 Colorimetry, 3 potentiometry 4 second derivative UV spectrophotometry, 5 HPLC, [6][7][8] solid phase extraction, 9 GC, 10 micellar RPLC, 11 LC-MS, 12 LC-MS-MS 13 and CZE 14 are applied for determination of cyclizine. The lack of the requisite sensitivity and/or selectivity, large sample volumes and complex procedures are the limitations of some of these methods.…”
Section: Introductionmentioning
confidence: 99%