2018
DOI: 10.1016/j.ijepes.2018.06.027
|View full text |Cite
|
Sign up to set email alerts
|

An optimal reactive power control method for distribution network with soft normally-open points and controlled air-conditioning loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 29 publications
0
12
0
1
Order By: Relevance
“…In (21) and (22), V IGBT is the voltage across the collector and emitter of the IGBT, E ON and E OFF are turn-on and turn-off losses of the IGBTs, respectively, f sw is the switching frequency, I C, nom is the nominal collector current of the IGBT, E rr is the turn off (reverse recovery) loss of the diodes, and r IGBT is the lead resistance of the IGBT. Besides, in (20), I i, t conv is the root-meansquare value of the current at the converter's AC terminal connected to the node i at period t and is calculated as follows:…”
Section: Principle and Modelling Of Sopsmentioning
confidence: 99%
See 1 more Smart Citation
“…In (21) and (22), V IGBT is the voltage across the collector and emitter of the IGBT, E ON and E OFF are turn-on and turn-off losses of the IGBTs, respectively, f sw is the switching frequency, I C, nom is the nominal collector current of the IGBT, E rr is the turn off (reverse recovery) loss of the diodes, and r IGBT is the lead resistance of the IGBT. Besides, in (20), I i, t conv is the root-meansquare value of the current at the converter's AC terminal connected to the node i at period t and is calculated as follows:…”
Section: Principle and Modelling Of Sopsmentioning
confidence: 99%
“…This performance yields an improved operation of SDG within which the ending points of feeders are more susceptible to undervoltage issues due to longest path from the feeding points. To this end, an optimal reactive power control method has been proposed in [22] for distribution systems which is equipped with SOPs considering the direct load control of thermostatic loads. In [23], a hybrid bi-level optimisation method has been proposed for multi-objective supply restoration in the SDGs with SOPs, where the proposed model is formulated as a typical mixed-integer non-linear programming problem.…”
Section: Introductionmentioning
confidence: 99%
“…Foreign researches on energy interconnection focus on the content and characteristics of energy interconnection, on-site practice results of energy interconnection, practical significance and composition of energy interconnection, etc., and relevant researches have achieved certain results [4]. In literature [5], the author discusses the characteristics and related control of new energy distribution network under the Internet, and analyzes the characteristics of this type of distribution network from the aspects of basic mode, structure and information requirements.…”
Section: Introductionmentioning
confidence: 99%
“…In [33, 34], the authors propose an optimal operation of SOPs in ADNs under three‐phase unbalanced conditions, and the flexible interconnection based on a multi‐terminal SOP significantly benefits the operation of ADNs by using the second‐order cone programming (SOCP)‐based method. In [35], the authors propose an optimal reactive power control method for distribution systems with SOPs and consider the direct load control of thermostatically controlled air‐conditioning. In [36], a two‐stage adjustable robust optimisation model with operational strategies of SOP is built to tackle the uncertainties of photovoltaics (PV) outputs.…”
Section: Introductionmentioning
confidence: 99%