Analog receive signal processing for magnetic particle imaging

Abstract: By recovering the full particle signal the SNR can be improved and errors in the x-space reconstruction are prevented. The authors show that the combined method provides this full particle signal and makes it possible to improve image quality.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
49
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 59 publications
(51 citation statements)
references
References 20 publications
2
49
0
Order By: Relevance
“…A total cancellation of the drive field feed‐through up to −125 dB was achieved (Table ). Eighth‐order band stop filters are theoretically able to suppress the drive field frequency band by up to 160 dB . Thus, the combined feed‐through suppression that is reported here is close to the damping by analog filters.…”
Section: Discussionsupporting
confidence: 65%
See 1 more Smart Citation
“…A total cancellation of the drive field feed‐through up to −125 dB was achieved (Table ). Eighth‐order band stop filters are theoretically able to suppress the drive field frequency band by up to 160 dB . Thus, the combined feed‐through suppression that is reported here is close to the damping by analog filters.…”
Section: Discussionsupporting
confidence: 65%
“…Additionally, the receive chain usually features a narrow band‐stop filter to cancel the direct drive field feed‐through that is orders of magnitudes higher than the particle signal. The feed‐through would render SPION detection impossible, due to the limited dynamic range of the analog‐to‐digital converter (ADC) as well as possible damage/saturation to the receive electronics …”
Section: Introductionmentioning
confidence: 99%
“…As pointed out by Graeser et al [10], when using the cancellation technique with a gradiometer, it is essential that the cancellation signal received by the gradiometer coil has the same phase and amplitude as the induced excitation signal.…”
Section: Discussionmentioning
confidence: 99%
“…We developed a simple and practical me-thod for correcting the inhomogeneous sensitivity of a receiving coil together with the feed through interference using a blank scan [9]. By combining the filtering method adopted by Graeser et al [10] and our method [9], we would expect that the reliability of our MPI system can be further enhanced. In this study, we investigated the effect of signal filtering with various analog filter modes on the image quality and quantitativity of the MPI images obtained by our projection-based MPI system using phantom studies.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation