Analysis of a Dynamic Voltage Compensator With Reduced Switch-Count and Absence of Energy Storage System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
14
0
1

Year Published

2009
2009
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(15 citation statements)
references
References 9 publications
0
14
0
1
Order By: Relevance
“…The DVR topologies with no energy storage take advantage of the remaining utility power for compensation. The location of the passive convertereither on the supply side or the load side bifurcates the storageless DVR topology into supply side connected DVR and load side connected DVR as shown in Figures 7(a) and 7(b), respectively [50][51][52][53][54]. It is proved theoretically and experimentally that the load side connected shunt converter DVR is superior among all the topology classification based on energy storage [10,21,46,49,55,56].…”
Section: Topologies Of Dvrmentioning
confidence: 93%
“…The DVR topologies with no energy storage take advantage of the remaining utility power for compensation. The location of the passive convertereither on the supply side or the load side bifurcates the storageless DVR topology into supply side connected DVR and load side connected DVR as shown in Figures 7(a) and 7(b), respectively [50][51][52][53][54]. It is proved theoretically and experimentally that the load side connected shunt converter DVR is superior among all the topology classification based on energy storage [10,21,46,49,55,56].…”
Section: Topologies Of Dvrmentioning
confidence: 93%
“…Additionally, while much work has been done on the effects and the measurements of voltage sags in the last decade [6,[9][10][11], little work has been published on the compensating methods of each type of electrical equipments when voltage sag occurs. As the ever-increasing in the economics development, lots of researchers devoted themselves to searching for effective ridethrough methods of those sensitive to power-disturbances devices [12][13][14][15][16][17][18]. Except Kelley et al [16] and Andrada et al [17], the main researching objective of most of them was usually not aimed at contactor.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, low-voltage / low-power series compensators for sag mitigation have been introduced and commercialized by several companies [2][3]. These equipments insert a compensating voltage between the faulty grid and the load in order to restore the voltage amplitude at the load-end.…”
Section: Introductionmentioning
confidence: 99%