2016
DOI: 10.1098/rsif.2015.0932
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of blink dynamics in patients with blepharoptosis

Abstract: Owing to the rapid movements of the human upper eyelid, a high-speed camera was used to record and characterize voluntary blinking and the blink dynamics of blepharoptosis patients were compared to a control group. Twenty-six blepharoptosis patients prior to surgery and 45 control subjects were studied and the vertical height of the palpebral aperture (PA) was measured manually at 2 ms intervals during each blink cycle. The PA and blinking speed were plotted with respect to time and a predictive model was gene… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(19 citation statements)
references
References 14 publications
0
19
0
Order By: Relevance
“…Previous studies have shown this noninvasive videography technique to be a reliable and accurate method of measuring blink dynamics. 11 , 16 …”
Section: Discussionmentioning
confidence: 99%
“…Previous studies have shown this noninvasive videography technique to be a reliable and accurate method of measuring blink dynamics. 11 , 16 …”
Section: Discussionmentioning
confidence: 99%
“…Traditionally, the eye blink was assessed by procedures requiring the application of electrodes to monitor the OO electromyographic activity and get the EOG signal [ 20 26 ], or the use of direct magnetic search coil technique [ 27 30 ]. Nevertheless, contact-free recording procedures such as photo or video, that permit a quantitative assessment for eye movement during blinking without interfering with the subject, have also been used [ 2 , 3 , 13 , 17 , 18 , 31 47 ].…”
Section: Introductionmentioning
confidence: 99%
“…The image capture rate used in this study is lower than what has been previously used [9] , [10] for eyelid tracking (600 fps). Despite the lower capture rate, the software was successfully able to locate the eyelids in each frame and track excursion.…”
Section: Resultsmentioning
confidence: 90%
“…Concurrently, processing power has increased making analysis of the thousands of image frames recorded at high frame rates feasible. High-speed image capture has been successfully employed to record and measure eyelid location during a single, voluntary blink in both healthy subjects [9] and in patients with blepharoptosis [10] . However, to the authors’ knowledge, no study has used high-speed image capture to study reflexive blinks.…”
Section: Introductionmentioning
confidence: 99%