2015 Australasian Universities Power Engineering Conference (AUPEC) 2015
DOI: 10.1109/aupec.2015.7324831
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system

Abstract: Abstract-Substation plays an important role in power system communications for safe and reliable operation of entire power networks. Substation communication networks are connected with various substation intelligent electronic devices (IEDs), which is substation systems lifeblood and the system availability is decided by its real-time performance. International Electrotechnical Commission (IEC) has been developed the standards based on object-oriented technologies for substation automation. IEC 61850 protocol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Therefore, in this practical application, the latency was highly affected by the network architecture, network bandwidth, data package, interval of data transmission (sampling rate) and the configuration of devices [33]. The authors of References [34][35][36][37][38] presented the performance and latency tests based on different architectures between substations, the tests showed promising results with Energies 2019, 12, 1442 20 of 23 only a few milliseconds of delay for peer to peer communication. However, such architecture might only be suitable for local area networks.…”
Section: Results Compared With Standardsmentioning
confidence: 99%
“…Therefore, in this practical application, the latency was highly affected by the network architecture, network bandwidth, data package, interval of data transmission (sampling rate) and the configuration of devices [33]. The authors of References [34][35][36][37][38] presented the performance and latency tests based on different architectures between substations, the tests showed promising results with Energies 2019, 12, 1442 20 of 23 only a few milliseconds of delay for peer to peer communication. However, such architecture might only be suitable for local area networks.…”
Section: Results Compared With Standardsmentioning
confidence: 99%
“…The papers [1], [2], [29] discuss the reliability, availability and data traffic flow performance of IEC-61850 based SCN. The reliability and availability performance is evaluated using the RBD while Optimised Network Engineering Tools (OPNET) software is used in [27], [30], [39]- [43], [31]- [38]. In the studies presented in [27], [30], [39]- [43], [31]- [38], system diagnostic coverage is not considered in the evaluation of the system reliability performance [2], [6].…”
Section: A Reliability Availability and Evaluation Methodsmentioning
confidence: 99%
“…The LNs have been explained in the IEC 61850-7-4. mentioning the first letter in the name of each LD shows the type of equipment [43]. For instance, X is used for the switchgear section and XCBR is a circuit breaker [44].…”
Section: Iec 61850 Overviewmentioning
confidence: 99%