2006
DOI: 10.1080/00032710600669358
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Explosives in Soil Using Solid Phase Microextraction and Gas Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…Homogenized soil samples (1 g) were weighed into vials and spiked with the standard solutions of TNT or 2,4-DNT at three concentration levels (0.5, 3, and 10 μg·mL –1 ). After being spiked, the soil samples were placed in a fume hood to allow the solvent to evaporate and were then allowed to stand for at least 1 h, as stated in previous reports, , to ensure the complete interaction of the analytes with the matrix of the sample.…”
Section: Methodsmentioning
confidence: 99%
“…Homogenized soil samples (1 g) were weighed into vials and spiked with the standard solutions of TNT or 2,4-DNT at three concentration levels (0.5, 3, and 10 μg·mL –1 ). After being spiked, the soil samples were placed in a fume hood to allow the solvent to evaporate and were then allowed to stand for at least 1 h, as stated in previous reports, , to ensure the complete interaction of the analytes with the matrix of the sample.…”
Section: Methodsmentioning
confidence: 99%
“…The two major separation methods frequently used for the determination of explosives are gas chromatography (GC) [9][10][11][12][13][14] and liquid chromatography (LC) [15][16][17][18][19][20][21][22][23] coupled with various detection techniques. Among these, LC-mass spectrometry (MS) is most often used in complex matrices, as the high temperatures of most GC techniques often leads to decomposition of the explosive compounds [17].…”
Section: Introductionmentioning
confidence: 99%
“…SPME was also used to identify the dominant odor chemicals emanating from explosives for use in developing optimal training aid combinations and mimics for canine detection (221) and to differentiate between different smokeless powders using SPME-GC/MS and SPME-GC-ECD in order to improve training aids for explosives detection canines (222). SPME coupled to GC was also used in the analysis of explosives in soil (223). Chemical ionization tandem mass spectrometry (CI-MS/MS) was used to improve on the detection of organic explosives (224).…”
Section: Trace Evidencementioning
confidence: 99%