2013
DOI: 10.4028/www.scientific.net/amr.791-793.623
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of External Gear Pump Failure

Abstract: Several typical failures of external gear pump are presented. The reasons of the pump failure are analyzed in detail. Solutions of the failure are proposed. In order to improve the efficiency of pumps maintenance and reparation, a new kind of tool is mentioned which could predict the life of gear pump before failure occurred.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In addition to single-component failures, there are also some combined failures. By analyzing the structure and working principle of the external gear hydraulic pump, Zhang et al [24] analyzed the failure of the external gear pump and proposed corresponding failure solutions. Das et al [25] analyzed the microscopic cause of rapid wear of hydraulic pumps from the influence of the microstructure of hydraulic gear pump on the corrosion wear behavior of materials.…”
Section: Fault Analysis Of Hydraulic Pumpmentioning
confidence: 99%
“…In addition to single-component failures, there are also some combined failures. By analyzing the structure and working principle of the external gear hydraulic pump, Zhang et al [24] analyzed the failure of the external gear pump and proposed corresponding failure solutions. Das et al [25] analyzed the microscopic cause of rapid wear of hydraulic pumps from the influence of the microstructure of hydraulic gear pump on the corrosion wear behavior of materials.…”
Section: Fault Analysis Of Hydraulic Pumpmentioning
confidence: 99%
“…Figure 1 shows the external gear pump and all its components. What is necessary to know is that there must be precisely defined axial and radial gaps between the gears and the pump body so that the gears can move flexibly inside the pump, within a few microns [1,21,39], while radial the clearances between the pump housing and the sleeve for high-pressure pumps are from 0.015 mm to 0.025 mm of the shaft sleeve diameter. Zhao and Vacca [40], based their theoretical research on the flow of an external gear pump via the CFD model and cited clearances as a parameter that directly affects the pump efficiency.…”
Section: Pressure-temperature-flow Characteristics Of the Pump Testmentioning