2009
DOI: 10.1016/j.jfoodeng.2008.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of heat transfer during ohmic processing of a solid food

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
60
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 95 publications
(63 citation statements)
references
References 11 publications
(13 reference statements)
3
60
0
Order By: Relevance
“…After a 2-min equilibration period, required to ensure a uniform heat distribution within the oven after the door was opened to allow sample introduction, samples were cooked by applying a constant voltage of 50 V to the electrodes. This is a lower voltage than used in previous studies (Marra et al 2009;Shirsat et al 2004); the reduction was necessary due to the relatively high electrical conductivity of the brine-injected meat. Two ohmic-heating protocols were applied (1) an LTLT treatment where the meat was ohmically heated (5 min) to a target temperature of 70°C at the coldest measured location followed by holding in air at 80°C for 8 min to give a total residence time of 15 min in the hot air cabinet and (2) an HTST treatment where the meat was ohmically heated (6 min) to a target temperature of 95°C with a total residence time of 8 min.…”
Section: Development Of Ohmic and Conventional Cooking Protocolsmentioning
confidence: 91%
See 2 more Smart Citations
“…After a 2-min equilibration period, required to ensure a uniform heat distribution within the oven after the door was opened to allow sample introduction, samples were cooked by applying a constant voltage of 50 V to the electrodes. This is a lower voltage than used in previous studies (Marra et al 2009;Shirsat et al 2004); the reduction was necessary due to the relatively high electrical conductivity of the brine-injected meat. Two ohmic-heating protocols were applied (1) an LTLT treatment where the meat was ohmically heated (5 min) to a target temperature of 70°C at the coldest measured location followed by holding in air at 80°C for 8 min to give a total residence time of 15 min in the hot air cabinet and (2) an HTST treatment where the meat was ohmically heated (6 min) to a target temperature of 95°C with a total residence time of 8 min.…”
Section: Development Of Ohmic and Conventional Cooking Protocolsmentioning
confidence: 91%
“…In order to minimise heat losses from the product's outer surfaces (including electrode contact areas) and to ensure product safety, a combined ohmic/convection heating system was developed. Such heat losses were examined by Marra et al (2009). The heating cell was housed in a fan-assisted convection oven (Gallenkamp hotbox; AGB Scientific Ltd., Dublin, Ireland) which was set at 80 or 100°C as required.…”
Section: Heating Equipmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Ohmic heating of food products involves the direct application of alternating current in order to generate internal heat as the result of electrical resistance (Chen, Abdelrahim, & Beckerich, 2010;Zhu, Zareifard, Chen, Marcotte, & Grabowski, 2010). Its advantages compared to conventional heating include a more uniform and faster heating, higher energy efficiency, technical simplicity and low capital and maintenance cost, and higher retention of the nutritional value of food (Marra, Zell, Lyng, Morgan, & Cronin, 2009;Stancl & Zitny, 2010;Vikram, Ramesh, & Prapulla, 2005).…”
Section: Introductionmentioning
confidence: 99%
“…2010;Bansal and Chen. 2006); carrot and radish (Zhu et al (2010)); potato (Marra et al (2009);Zhu et al (2010); Ye et al (2004)); apple, orange, and pineapple juices (Amiali et al (2006)); beetroot (Lima et al (2001)); grape juice (Icier et al (2008)); egg products (Darvishi et al (2012a, b)); Icier and Bozkurt (2009); chicken (Tulsiyan et al (2008)); Sarang et al (2008)), beef and meat (Zhu et al (2010); Bozkurt and Icier (2010); Icier and Ilicali (2005a)); Sarang et al (2008)). …”
Section: Introductionmentioning
confidence: 99%