2017
DOI: 10.1016/j.jmir.2016.10.012
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Influence of Errors in Angular Settings of Couch and Collimator on the Dosimetric and Radiobiological Parameters in VMAT Plans

Abstract: Objective: To evaluate the impact of couch and collimator angular variations on dose volume histogram (DVH), tumour control probability (TCP), and normal tissue complication probability (NTCP) of the volumetric-modulated arc therapy (VMAT) plans. Methods: Stereotactic radiosurgery and stereotactic body radiation therapy VMAT plans were generated for three different hypothetical planning target volumes (PTVs) that mimic brain metastases, single brain lesion, and single spine lesion. Thirty routine VMAT plans (1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 34 publications
0
1
0
Order By: Relevance
“…[6][7][8] In addition, MLC positional errors or small calibration errors in the angular settings of the collimator, couch or gantry may create difference in dose delivery. [9][10][11] In combination, the patient setup variations and the machine delivery errors may produce a delivered dose different from that of the planned dose. These effects are especially significant in VMAT techniques, where there is a steep dose gradient between the tumour and the organ at risk (OAR).…”
Section: Introductionmentioning
confidence: 99%
“…[6][7][8] In addition, MLC positional errors or small calibration errors in the angular settings of the collimator, couch or gantry may create difference in dose delivery. [9][10][11] In combination, the patient setup variations and the machine delivery errors may produce a delivered dose different from that of the planned dose. These effects are especially significant in VMAT techniques, where there is a steep dose gradient between the tumour and the organ at risk (OAR).…”
Section: Introductionmentioning
confidence: 99%