2018
DOI: 10.3390/molecules23051056
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Menaquinone-7 Content and Impurities in Oil and Non-Oil Dietary Supplements

Abstract: Rapid, global technological development has caused the food industry to use concentrated food component sources like dietary supplements ever more commonly as part of the human diet. This study analysed the menaquinone-7 (MK-7) content of dietary supplements in oil capsule and hard tablet forms. A novel method for separating and measuring geometric isomers of MK-7 in dietary supplements was developed and validated. Eleven different isomers of cis/trans- menaquinone-7 were identified. Identification of cis/tran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 37 publications
0
19
2
Order By: Relevance
“…Relative to traditional MK-7 analytical techniques, which do not consider the isomer composition of samples, the analysis and measurement of MK-7 isomers present various difficulties. The fundamental issue is the absence of specific analytical standards for the potential cis forms of the vitamin, as only the all-trans MK-7 standard is commercially available [8,36]. As a result, the identification and quantification of cis MK-7 pose a challenge due to the lack of appropriate reference standards.…”
Section: Lc-ms Analysismentioning
confidence: 99%
See 3 more Smart Citations
“…Relative to traditional MK-7 analytical techniques, which do not consider the isomer composition of samples, the analysis and measurement of MK-7 isomers present various difficulties. The fundamental issue is the absence of specific analytical standards for the potential cis forms of the vitamin, as only the all-trans MK-7 standard is commercially available [8,36]. As a result, the identification and quantification of cis MK-7 pose a challenge due to the lack of appropriate reference standards.…”
Section: Lc-ms Analysismentioning
confidence: 99%
“…However, it is essential to note that, like most biological molecules, MK-7 can exist as geometric isomers, of which only the naturally occurring all-trans isomer is bioactive [6,8,36]. The double bond arrangement in the isoprenoid side chain of MK-7 molecules determines its shape and, consequently, its biological activity [6,37].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The regression coefficient for all calibration curves was greater than 0.999 (Figure 2a-d). The obtained results were better than those found in the literature, which considers that a regression coefficient above 0.99 is satisfactory [15][16][17][18][19][20][21][22][23]. The LOD and LOQ of the target analytes are presented in Table 2.…”
Section: Chromatographic Parametersmentioning
confidence: 67%