2012
DOI: 10.1002/cnm.2478
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of micro fracture in human Haversian cortical bone under compression

Abstract: A procedure to investigate local stress intensity factors in human Haversian cortical bone under compression is presented. The method combines a customised experimental setting for micro-compression tests of millimetric bone specimens and a finite element contact model conforming to the bone morphology that tracks advancing microcracks. The non-interpenetration conditions along the crack edges are ensured by penalty constraints of which the parameters are optimised for minimum contact pressure error with respe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 66 publications
0
20
0
Order By: Relevance
“…The generated meshes with a 10 μm resolution were exported into an FEM software [55]. The fresh bone mechanical properties and stress field were identified through a dual experimental and numerical method that followed a top-down approach in order to validate theoretical hypotheses on the multi-scale failure mechanisms [56,57] in 2D and 3D. The local elastic Young's moduli were correlated to the phase mineral content that was correlated to the local grey scale averaged in each osteon [58,59,60,61,62,63].…”
Section: Hierarchical Multiscale Model Of Osteocyte 3d Microenvironmentmentioning
confidence: 99%
See 2 more Smart Citations
“…The generated meshes with a 10 μm resolution were exported into an FEM software [55]. The fresh bone mechanical properties and stress field were identified through a dual experimental and numerical method that followed a top-down approach in order to validate theoretical hypotheses on the multi-scale failure mechanisms [56,57] in 2D and 3D. The local elastic Young's moduli were correlated to the phase mineral content that was correlated to the local grey scale averaged in each osteon [58,59,60,61,62,63].…”
Section: Hierarchical Multiscale Model Of Osteocyte 3d Microenvironmentmentioning
confidence: 99%
“…The Poisson's ratios were determined by microextensometry with a mean value of 0.23 and a standard deviation of 0.04 and were inversely correlated to the phase grey levels [56,57]. The local Poisson ratio of osteon I was therefore calculated as follows:…”
Section: Hierarchical Multiscale Model Of Osteocyte 3d Microenvironmentmentioning
confidence: 99%
See 1 more Smart Citation
“…To further extend the study, cracks of different sizes were numerically induced in the bone to gauge the utility of the NBPS (vis‐à‐vis DBPS) in determining the extent of this kind of damage in bones that occurs during accidents. Previously, Jonvaux et al proposed a method that combined customized experimental setting for microcompression tests of millimetric bone specimens and a finite element contact model conforming to the bone morphology that tracked advancing microcracks. In the present study, the size of the crack was varied from 2‐mm spherical crack to 10‐mm spherical crack.…”
Section: Parametric Study Of Bone Degradation Monitoring Using Nbpsmentioning
confidence: 99%
“…Beno et al [77] is calculated by using equations (16)(17) [78]. Equation (15) is applied when i and j are 1, 2, 3 or 6…”
Section: Step 6: Laminate With Lrc Lamellaementioning
confidence: 99%