2012
DOI: 10.1016/j.chroma.2012.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of multiple quaternary ammonium compounds in the brain using tandem capillary column separation and high resolution mass spectrometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(31 citation statements)
references
References 45 publications
0
31
0
Order By: Relevance
“…Falasca et al . () used microwave irradiation to rapidly terminate the enzyme activity in the brain tissue of shrews. This maintains the levels of endogenous QACs and allows for more accurate analysis.…”
Section: Sample Preparationmentioning
confidence: 99%
“…Falasca et al . () used microwave irradiation to rapidly terminate the enzyme activity in the brain tissue of shrews. This maintains the levels of endogenous QACs and allows for more accurate analysis.…”
Section: Sample Preparationmentioning
confidence: 99%
“…Among the different possibilities to combine HILIC to RPLC, serial coupling is an easy setting, which does not require the use of specific interfaces, such as valve‐switching systems used in 2D chromatography. To the best of our knowledge, only three serial RPLC–HILIC coupled methods have been described in the literature so far, and just two of them have been applied to real matrices . Serial RPLC–HILIC coupled methods are emerging as a reliable technique, with a great potential to find application in several fields for the analysis of complex samples by a single injection .…”
Section: Introductionmentioning
confidence: 99%
“…To the best of our knowledge, only three serial RPLC–HILIC coupled methods have been described in the literature so far, and just two of them have been applied to real matrices . Serial RPLC–HILIC coupled methods are emerging as a reliable technique, with a great potential to find application in several fields for the analysis of complex samples by a single injection . However, more investigations are required to establish the versatility of such methods.…”
Section: Introductionmentioning
confidence: 99%
“…(polyhydroxyethyl aspartamide) HILIC column, was used for the analysis of 11 quaternary ammonium compounds in brain extracts, including acylcarnitines of low polarity. To overcome the mobile phase compatibility problem on the two columns, they were connected via a T-piece allowing addition of a make-up flow of 95% acetonitrile to the effluent from the RP column before transfer to the HILIC column (Falasca et al, 2012). …”
Section: Chapter 2 Advances In Hydrophilic Interaction Liquid Chromatmentioning
confidence: 99%