A drenal hypertension caused by primary aldosteronism comprises the most common curable form of secondary hypertension. In the analytic workup of patients with primary aldosteronism, adrenal venous sampling (AVS) is recommended for establishing the origins of excess production of hormones.1 AVS is a technically demanding procedure in which correct cannulation of the adrenal veins, especially the right, can pose significant difficulty. 2,3 Correct positioning of the catheter is verified by measurement of plasma cortisol concentrations. High cortisol concentrations in adrenal blood compared with peripheral blood ascertain correct catheter placement and thus selective sampling. Because cortisol has a long circulating halflife (100 minutes), increases in adrenal vein (AV) blood above levels of peripheral venous (PV) blood are relatively minor and subsequently subject to interpretative error. Furthermore, as a result of physiological corticotropin fluctuations, cortisol is secreted in a variable fashion so that fluctuating levels can interfere with the interpretation of AVS selectivity. [4][5][6] This problem can be overcome using cosyntropin stimulation. 7 Cosyntropin stimulation, however, adds to the complexity of the procedure and for this reason is not always used.With the above considerations in mind, there seems a need for more reliable parameters than cortisol in assessing the correct positioning of catheters during AVS.8 Plasma metanephrine, the O-methylated metabolite of epinephrine, represents one such alternative analyte. More than 90% of plasma metanephrine is produced within the adrenal medulla, with <10% produced from epinephrine after release from the adrenals. 7 Compared with cortisol, plasma metanephrine has a short circulating half-life of 3 to 6 minutes, resulting in close to 90-fold increases of AV compared with PV concentrations in situations where catheters are correctly positioned.7 Such large Abstract-Adrenal vein sampling is used to establish the origins of excess production of adrenal hormones in primary aldosteronism. Correct catheter positioning is confirmed using adrenal vein measurements of cortisol, but this parameter is not always reliable. Plasma metanephrine represents an alternative parameter. The objective of our study was to determine the use of plasma metanephrine concentrations to establish correct catheter positioning during adrenal vein sampling with and without cosyntropin stimulation. We included 52 cosyntropin-stimulated and 34 nonstimulated sequential procedures. Plasma cortisol and metanephrine concentrations were measured in adrenal and peripheral venous samples. Success rates of sampling, using an adrenal to peripheral cortisol selectivity index of 3.0, were compared with success rates of metanephrine using a selectivity index determined by receiver operating characteristic curve analysis. Among procedures assessed as selective using cortisol, the adrenal to peripheral vein ratio of metanephrine was 6-fold higher than that of cortisol (94.0 versus 15.5; P<0.0001). Ther...