1959
DOI: 10.2172/4232084
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Self-Shutdown Behavior in the Spert I Reactor

Abstract: Portions of this document may be illegible in electronic image products. Images are produced from the best available original document. f-LEGAL N O T I C I B. Armnw q IiatiilitM $6 msgea to we d, or for s~l , u t t j a f~m tllc use d .~llr Sofmmati~n. w t u a .-hod, OP pmwm d k i o s d JEdt m t. h s u a e d i n~r r b P m ' '~~~t i r y (o n B c h n l f o f t h o G ' ' ''inchtdslaagmnpbpor ~o f t h c~4 n , o r~d~o o n~, t b 1 1 M~l r b. t~c r a p b f f C or mtrclctar o f the CoraBlish, or wn@lo~et pP ruch wntrae… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1961
1961
1961
1961

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Past experience has shown that the set of parameters V -2.47, r] -2.08, and a = 0.184 describes a consistent set at thermal energies. Therefore, associated with Amster's value of G?^^, the value of CJp was 15 adjusted to fit a = 0.182 at the softest available spectrum (zero voids, thin fuel elements); the subsequent relative variation of crf/ag, as given by Amster's compilation was maintained.…”
Section: Thermal Cross Sectionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Past experience has shown that the set of parameters V -2.47, r] -2.08, and a = 0.184 describes a consistent set at thermal energies. Therefore, associated with Amster's value of G?^^, the value of CJp was 15 adjusted to fit a = 0.182 at the softest available spectrum (zero voids, thin fuel elements); the subsequent relative variation of crf/ag, as given by Amster's compilation was maintained.…”
Section: Thermal Cross Sectionsmentioning
confidence: 99%
“…14, The void coefficient with 10 grams boric acid and reactor cold is still negative (even though substantially smaller in magnitude than with no boric acid); Ak/Av = -0.12 (0 gm/gal), -0,085 (5 gm/gal), -0.045 (10 gm/gal). 15. The management of the boric acid system will probably be as follows:…”
Section: The B-ss Strips Should Be Located As Shown Inmentioning
confidence: 99%
“…(5) Check that the dial settings for the high flux trip levels are correct. These should correspond to 120% of normal operating power on Channel IV Safety Trip A and Channel V Safety Trip B, and 90% of full scale on Channel VI Safety Trip C. (6) Check that the period trip (10 sec) operates using the periodcheck switch if shutdown has been for an extended period.…”
Section: Normal Startup Proceduresmentioning
confidence: 99%
“…The pool portion of t h e f a c i l i t y i s made lly, of two 50,000 g a l capacity tanks. The pools a r e f a b r i c a t e d from5/16 i n . t h i c k s t a i n l e s s s t e e l and a r e designed f o r 25 f t of h y d r o s t a t i c l o a d plus a 50 p s i overpressure.…”
mentioning
confidence: 99%