1961
DOI: 10.2172/4768935
|View full text |Cite
|
Sign up to set email alerts
|

Spert Iv Hazards Summary Report

Abstract: T I & nport'was prepared as an account of Government sponsored work. Ntithex the United Stater, nor the Comxi&siuu, nor any person acting en behalf d the Commbion: A. Makes any warranty or representation, ex* or implied, with respect to the accuracy, completeness, or usefulness of the information contained in this report, or that the urre of any information, apparatus, method, or process disclosed in this report may not infringe privately owned tights: ur B. Assumes any liabilities with respect to the use of, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1964
1964
1965
1965

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…During the P core test series, measurements were made of reactor power, fuel plate surface temperature, and pressure [13]. A block diagram of the transient instrumentation is shown in Figure 15.…”
Section: Instrumentationmentioning
confidence: 99%
“…During the P core test series, measurements were made of reactor power, fuel plate surface temperature, and pressure [13]. A block diagram of the transient instrumentation is shown in Figure 15.…”
Section: Instrumentationmentioning
confidence: 99%
“…[a] The meat section was composed of uo 2 The plates were separated by a nominal 133 mils of moderator water. Further detail of the core design may be found in a previously published report [13].…”
Section: Core Description [13jmentioning
confidence: 99%
“…This report presents a description of a Capsule Driver Core and an analysis of the possible hazards involved in its operation. Inasmuch as the major change to the Spert IV facility is the replacement only of the core, this report is written as an addendum to the original Spert IV Hazards Summary Report [4] as well as the other supplementary information [5,6] supplied to the Atomic Energy Commission at the time of the original review of the safety of operation of Spert IV. Information contained in the previous submission to the AEC for safety review purposes which is not pertinent, altered, or negated by installation of the Capsule Driver Core (CDC) in the Spert IV facility is not reproduced in this report except for excerpts or abbreviated discussions which are presented for• c..:ompleleness.…”
Section: Introductionmentioning
confidence: 99%