Abstract: In order to reduce the cost of the produced electricity, the Linear Fresnel Collector (LFC) system is a promising Concentrated Solar Power (CSP) technology. In this paper a detailed study is conducted aimed at the assessment of the heat losses from the receiver of a real 1 MWe pilot plant based on the Fresnel collector and cooled with a thermal oil. The receiver unit, which consists of an absorber tube and a compound parabolic concentrator (CPC), is investigated numerically in order to determine the receiver p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…As stated in the results, the maximum exergy performance is on the condition of 700 K. Also, a parametric study for identifying the thermal performance of a LFR has been carried out by A. Barbon et al The considered parameters are mirror length and width, and receiver height. Cagnoli et al numerically analyzed the performance of utilizing encapsulated tubes or evacuated tubes in the linear Fresnel collectors.…”
Section: Solar Thermal Power Generation Systems With Various Solar Comentioning
confidence: 99%
“…As stated in the results, the maximum exergy performance is on the condition of 700 K. Also, a parametric study for identifying the thermal performance of a LFR has been carried out by A. Barbon et al The considered parameters are mirror length and width, and receiver height. Cagnoli et al numerically analyzed the performance of utilizing encapsulated tubes or evacuated tubes in the linear Fresnel collectors.…”
Section: Solar Thermal Power Generation Systems With Various Solar Comentioning
confidence: 99%
“…Cagnoli et al. [6] evaluated the thermal losses of the tank of a real 1 MWe pilot plant. According to their outcomes, the advantage of utilizing evacuated tubes relies on the thermal energy attracted on linear tank, relying on position of the sun.…”
Section: Introductionmentioning
confidence: 99%
“…Numerical studies on Linear Fresnel Concentrator to determine absorber performance in different directs of wind done by Cagnoli et al [9]. Geometry of this research embraces absorber and glass tubes that space between them filled with air in 1 atm pressure.…”
Section: Introductionmentioning