2021
DOI: 10.1016/j.apacoust.2021.108237
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the simultaneous measurement of acoustic phase velocity and stress-strain relationship in beef: An approach to Young's modulus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
2
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 47 publications
1
2
0
1
Order By: Relevance
“…Figure 5b shows the evolution of the ultrasonic velocity during salting. In raw beef steaks, the average calculated velocity was 1622 m/s for the NC and 1584 m/s for the C techniques, which coincides with the figures previously reported for raw beef (Hara et al, 1979;Ludwig, 1950) and beef steaks (Diaz-Almanza et al, 2021;Marcus & Carstensen, 1975). Once the salting began, m/s).…”
Section: 2modification Of Ultrasonic Parameters During Saltingsupporting
confidence: 87%
“…Figure 5b shows the evolution of the ultrasonic velocity during salting. In raw beef steaks, the average calculated velocity was 1622 m/s for the NC and 1584 m/s for the C techniques, which coincides with the figures previously reported for raw beef (Hara et al, 1979;Ludwig, 1950) and beef steaks (Diaz-Almanza et al, 2021;Marcus & Carstensen, 1975). Once the salting began, m/s).…”
Section: 2modification Of Ultrasonic Parameters During Saltingsupporting
confidence: 87%
“…On the other hand, using non-contact transducers determined the velocity in a range between 1587 m/s and 1668 m/s in pork burger patties and considering different temperatures of measurements [11]. With regard to the results presented for the parameters related to frequency and attenuation, they are not comparable to other studies because these parameters were generally not considered, or when they were, the transducers and inspection geometries had different characteristics [14,29,30], which prevents comparison with the current results. ± 13 UPV = ultrasound pulse velocity; UPVE = ultrasound pulse velocity obtained from visible echoes; FFT25/FFT99 = frequency values from fast Fourier transform corresponding to the 25th and 99th percentiles; AT20/AT40/AT60/= attenuation parameters corresponding to reaching 20%, 40%, and 60% of the energy; α = attenuation coefficient; nv = means non-visible echoes.…”
Section: Physicochemical Results and Ultrasound Inspection Resultsmentioning
confidence: 75%
“…[56] More recently, methods have been investigated for measuring the physical properties of meat through nondestructive methods such as MRI and ultrasound. [57,58] Table 2 shows some examples of instrumental texture measurements taken from meat samples from various species.…”
Section: Quantifying Texturementioning
confidence: 99%